User Guide#

Introduction#

The ROCm Validation Suite (RVS) is a system administrator’s and cluster manager’s tool for detecting and troubleshooting common problems affecting AMD GPU(s) running in a high-performance computing environment, enabled using the ROCm software stack on a compatible platform.

The RVS is a collection of tests, benchmarks and qualification tools each targeting a specific sub-system of the ROCm platform. All of the tools are implemented in software and share a common command line interface. Each set of tests are implemented in a “module” which is a library encapsulating the functionality specific to the tool. The CLI can specify the directory containing modules to use when searching for libraries to load. Each module may have a set of options that it defines and a configuration file that supports its execution.

Installing RVS#

RVS can be obtained by building it from source code base or by installing from pre-built package.

Building from Source Code#

RVS has been developed as open source solution. Its source code and belonging documentation can be found at AMD’s GitHub page.\n In order to build RVS from source code please visit ROCm Validation Suite GitHub site and follow instructions in README file.

Installing from Package#

Please download rocm-validation-suite-$(RVSVER).deb or .rpt file from AMD site. Install package using your favorite package manager.

RVS components is installed in /opt/rocm/rvs. Package contains:

  • executable modules

  • user guide (located in in install-base/userguide/html)

  • man page (located in install-base/man)

  • configuration examples (located in install-base/conf)

If needed, you may remove RVS package using you favorite package manager.

Basic Concepts#

RVS Architecture#

RVS is implemented as a set of modules each implementing particular test functionality. Modules are invoked from one central place (aka Launcher) which is responsible for reading input (command line and test configuration file), loading and running appropriate modules and providing test output. RVS architecture is built around concept of Linux shared objects, thus allowing for easy addition of new modules in the future.

Available Modules#

GPU Properties – GPUP#

The GPU Properties module queries the configuration of a target device and returns the device’s static characteristics.\n These static values can be used to debug issues such as device support, performance and firmware problems.

GPU Monitor – GM module#

The GPU monitor tool is capable of running on one, some or all of the GPU(s) installed and will report various information at regular intervals. The module can be configured to halt another RVS modules execution if one of the quantities exceeds a specified boundary value.

PCI Express State Monitor – PESM module#

The PCIe State Monitor tool is used to actively monitor the PCIe interconnect between the host platform and the GPU. The module will register a “listener” on a target GPU’s PCIe interconnect, and log a message whenever it detects a state change. The PESM is able to detect the following state changes:

  1. PCIe link speed changes

  2. GPU power state changes

ROCm Configuration Qualification Tool - RCQT#

module The ROCm Configuration Qualification Tool ensures the platform is capable of running ROCm applications and is configured correctly. It checks the installed versions of the ROCm components and the platform configuration of the system. This includes checking that dependencies, corresponding to the associated operating system and run time environment, are installed correctly. Other qualification steps include checking:

  1. The existence of the /dev/kfd device

  2. The /dev/kfd device’s permissions

  3. The existence of all required users and groups that support ROCm

  4. That the user mode components are compatible with the drivers, both the KFD and the amdgpu driver.

  5. The configuration of the run time linker/loader qualifying that all ROCm libraries are in the correct search path.

PCI Express Qualification Tool – PEQT module#

The PCIe Qualification Tool consists is used to qualify the PCIe bus on which the GPU is connected. The qualification test is capable of determining the following characteristics of the PCIe bus interconnect to a GPU:

  1. Support for Gen 3 atomic completers

  2. DMA transfer statistics

  3. PCIe link speed

  4. PCIe link width

SBIOS Mapping Qualification Tool – SMQT module#

The GPU SBIOS mapping qualification tool is designed to verify that a platform’s SBIOS has satisfied the BAR mapping requirements for VDI and Radeon Instinct products for ROCm support.

Refer to the “ROCm Use of Advanced PCIe Features and Overview of How BAR Memory is Used In ROCm Enabled System” web page for more information about how BAR memory is initialized by VDI and Radeon products.

P2P Benchmark and Qualification Tool – PBQT module#

The P2P Benchmark and Qualification Tool is designed to provide the list of all GPUs that support P2P and characterize the P2P links between peers. In addition to testing for P2P compatibility, this test will perform a peer-to-peer throughput test between all P2P pairs for performance evaluation. The P2P Benchmark and Qualification Tool will allow users to pick a collection of two or more GPUs on which to run. The user will also be able to select whether or not they want to run the throughput test on each of the pairs.

Please see the web page “ROCm, a New Era in Open GPU Computing” to find out more about the P2P solutions available in a ROCm environment.

PCI Express Bandwidth Benchmark – PEBB module#

The PCIe Bandwidth Benchmark attempts to saturate the PCIe bus with DMA transfers between system memory and a target GPU card’s memory. The maximum bandwidth obtained is reported to help debug low bandwidth issues. The benchmark should be capable of targeting one, some or all of the GPUs installed in a platform, reporting individual benchmark statistics for each.

GPU Stress Test - GST module#

The GPU Stress Test runs a Graphics Stress test or SGEMM/DGEMM (Single/Double-precision General Matrix Multiplication) workload on one, some or all GPUs. The GPUs can be of the same or different types. The duration of the benchmark should be configurable, both in terms of time (how long to run) and iterations (how many times to run).

The test should be capable driving the power level equivalent to the rated TDP of the card, or levels below that. The tool must be capable of driving cards at TDP-50% to TDP-100%, in 10% incremental jumps. This should be controllable by the user.

Input EDPp Test - IET module#

The Input EDPp Test generates EDP peak power on all input rails. This test is used to verify if the system PSU is capable of handling the worst case power spikes of the board. Peak Current at defined period = 1 minute moving average power.

Configuration Files#

The RVS tool will allow the user to indicate a configuration file, adhering to the YAML 1.2 specification, which details the validation tests to run and the expected results of a test, benchmark or configuration check.

The configuration file used for an execution is specified using the --config option. The default configuration file used for a run is rvs.conf, which will include default values for all defined tests, benchmarks and configurations checks, as well as device specific configuration values. The format of the configuration files determines the order in which actions are executed, and can provide the number of times the test will be executed as well.

Configuration file is, in YAML terms, mapping of ‘actions’ keyword into sequence of action items. Action items are themselves YAML keyed lists. Each list consists of several key:value pairs. Some keys may have values which are keyed lists themselves (nested mappings).

Action item (or action for short) uses keys to define nature of validation test to be performed. Each action has some common keys – like ‘name’, ‘module’, ‘deviceid’ – and test specific keys which depend on the module being used.

An example of RVS configuration file is given here:

actions:
- name: action_1
  device: all
  module: gpup
  properties:
    mem_banks_count:
  io_links-properties:
    version_major:
- name: action_2
  module: gpup
  device: all
  properties:
    mem_banks_count:
- name: action_3
...

Common Configuration Keys#

Common configuration keys applicable to most module are summarized in the table below:\n

Config Key Type Description
nameStringThe name of the defined action.
deviceCollection of String This is a list of device indexes (gpu ids), or the keyword “all”. The defined actions will be executed on the specified device, as long as the action targets a device specifically (some are platform actions). If an invalid device id value or no value is specified the tool will report that the device was not found and terminate execution, returning an error regarding the configuration file.
deviceidIntegerThis is an optional parameter, but if specified it restricts the action to a specific device type corresponding to the deviceid.
parallelBoolIf this key is false, actions will be run on one device at a time, in the order specified in the device list, or the natural ordering if the device value is “all”. If this parameter is true, actions will be run on all specified devices in parallel. If a value isn’t specified the default value is false.
countIntegerThis specifies number of times to execute the action. If the value is 0, execution will continue indefinitely. If a value isn’t specified the default is 1. Some modules will ignore this parameter.
waitIntegerThis indicates how long the test should wait between executions, in milliseconds. Some modules will ignore this parameter. If the count key is not specified, this key is ignored. duration Integer This parameter overrides the count key, if specified. This indicates how long the test should run, given in milliseconds. Some modules will ignore this parameter.
moduleStringThis parameter specifies the module that will be used in the execution of the action. Each module has a set of sub-tests or sub-actions that can be configured based on its specific parameters.

Command Line Options#

Command line options are summarized in the table below:

Short optionLong option Description
-a\-\-appendLogWhen generating a debug logfile, do not overwrite the contents of a current log. Used in conjunction with the -d and -l options.
-c\-\-configSpecify the configuration file to be used. The default is \/RVS/conf/RVS.conf
\-\-configlessRun RVS in a configless mode. Executes a "long" test on all supported GPUs.
-d\-\-debugLevelSpecify the debug level for the output log. The range is 0 to 5 with 5 being the most verbose. Used in conjunction with the -l flag.
-g\-\-listGpusList the GPUs available and exit. This will only list GPUs that are supported by RVS.
-i\-\-indexesComma separated list of devices to run RVS on. This will override the device values specified in the configuration file for every action in the configuration file, including the "all" value.
-j\-\-jsonOutput should use the JSON format.
-l\-\-debugLogFileSpecify the logfile for debug information. This will produce a log file intended for post-run analysis after an error.
\-\-quietNo console output given. See logs and return code for errors.
-m\-\-modulepathSpecify a custom path for the RVS modules.
\-\-specifiedtestRun a specific test in a configless mode. Multiple word tests should be in quotes. This action will default to all devices, unless the \-\-indexes option is specifie.
-t\-\-listTestsList the modules available to be executed through RVS and exit. This will list only the readily loadable modules given the current path and library conditions.
-v\-\-verboseEnable verbose reporting. This is equivalent to specifying the -d 5 option.
\-\-versionDisplays the version information and exits.
-h\-\-helpDisplay usage information and exit.

GPUP Module#

The GPU properties module provides an interface to easily dump the static characteristics of a GPU. This information is stored in the sysfs file system for the kfd, with the following path:

/sys/class/kfd/kfd/topology/nodes/<node id>

Each of the GPU nodes in the directory is identified with a number, indicating the device index of the GPU. This module will ignore count, duration or wait key values.

Module Specific Keys#

Config Key Type Description
propertiesCollection of Strings The properties key specifies what configuration property or properties the query is interested in. Possible values are:\n all - collect all settings\n gpu_id\n cpu_cores_count\n simd_count\n mem_banks_count\n caches_count\n io_links_count\n cpu_core_id_base\n simd_id_base\n max_waves_per_simd\n lds_size_in_kb\n gds_size_in_kb\n wave_front_size\n array_count\n simd_arrays_per_engine\n cu_per_simd_array\n simd_per_cu\n max_slots_scratch_cu\n vendor_id\n device_id\n location_id\n drm_render_minor\n max_engine_clk_fcompute\n local_mem_size\n fw_version\n capability\n max_engine_clk_ccompute\n
io_links-propertiesCollection of Strings The properties key specifies what configuration property or properties the query is interested in. Possible values are:\n all - collect all settings\n count - the number of io_links\n type\n version_major\n version_minor\n node_from\n node_to\n weight\n min_latency\n max_latency\n min_bandwidth\n max_bandwidth\n recommended_transfer_size\n flags\n

Output#

Module specific output keys are described in the table below:

Output Key Type Description
properties-valuesCollection of Integers The collection will contain a positive integer value for each of the valid properties specified in the properties config key.
io_links-propertiesvaluesCollection of Integers The collection will contain a positive integer value for each of the valid properties specified in the io_links-properties config key.
Each of the settings specified has a positive integer value. For each setting requested in the properties key a message with the following format will be returned:
[RESULT][<timestamp>][<action name>] gpup <gpu id> <property> <property value>

For each setting in the io_links-properties key a message with the following format will be returned:

[RESULT][<timestamp>][<action name>] gpup <gpu id> <io_link id> <property> <property value>

Examples#

Example 1:

Consider action>

actions:
- name: action_1
  device: all
  module: gpup
  properties:
    all:
  io_links-properties:
    all:

Action will display all properties for all compatible GPUs present in the system. Output for such configuration may be like this:

[RESULT] [597737.498442] action_1 gpup 3254 cpu_cores_count 0
[RESULT] [597737.498517] action_1 gpup 3254 simd_count 256
[RESULT] [597737.498558] action_1 gpup 3254 mem_banks_count 1
[RESULT] [597737.498598] action_1 gpup 3254 caches_count 96
[RESULT] [597737.498637] action_1 gpup 3254 io_links_count 1
[RESULT] [597737.498680] action_1 gpup 3254 cpu_core_id_base 0
[RESULT] [597737.498725] action_1 gpup 3254 simd_id_base 2147487744
[RESULT] [597737.498768] action_1 gpup 3254 max_waves_per_simd 10
[RESULT] [597737.498812] action_1 gpup 3254 lds_size_in_kb 64
[RESULT] [597737.498856] action_1 gpup 3254 gds_size_in_kb 0
[RESULT] [597737.498901] action_1 gpup 3254 wave_front_size 64
[RESULT] [597737.498945] action_1 gpup 3254 array_count 4
[RESULT] [597737.498990] action_1 gpup 3254 simd_arrays_per_engine 1
[RESULT] [597737.499035] action_1 gpup 3254 cu_per_simd_array 16
[RESULT] [597737.499081] action_1 gpup 3254 simd_per_cu 4
[RESULT] [597737.499128] action_1 gpup 3254 max_slots_scratch_cu 32
[RESULT] [597737.499175] action_1 gpup 3254 vendor_id 4098
[RESULT] [597737.499222] action_1 gpup 3254 device_id 26720
[RESULT] [597737.499270] action_1 gpup 3254 location_id 8960
[RESULT] [597737.499318] action_1 gpup 3254 drm_render_minor 128
[RESULT] [597737.499369] action_1 gpup 3254 max_engine_clk_ccompute 2200
[RESULT] [597737.499419] action_1 gpup 3254 local_mem_size 17163091968
[RESULT] [597737.499468] action_1 gpup 3254 fw_version 405
[RESULT] [597737.499518] action_1 gpup 3254 capability 8832
[RESULT] [597737.499569] action_1 gpup 3254 max_engine_clk_ccompute 2200
[RESULT] [597737.499633] action_1 gpup 3254 0 count 1
[RESULT] [597737.499675] action_1 gpup 3254 0 type 2
[RESULT] [597737.499695] action_1 gpup 3254 0 version_major 0
[RESULT] [597737.499716] action_1 gpup 3254 0 version_minor 0
[RESULT] [597737.499736] action_1 gpup 3254 0 node_from 4
[RESULT] [597737.499763] action_1 gpup 3254 0 node_to 1
[RESULT] [597737.499783] action_1 gpup 3254 0 weight 20
[RESULT] [597737.499808] action_1 gpup 3254 0 min_latency 0
[RESULT] [597737.499830] action_1 gpup 3254 0 max_latency 0
[RESULT] [597737.499853] action_1 gpup 3254 0 min_bandwidth 0
[RESULT] [597737.499878] action_1 gpup 3254 0 max_bandwidth 0
[RESULT] [597737.499902] action_1 gpup 3254 0 recommended_transfer_size 0
[RESULT] [597737.499927] action_1 gpup 3254 0 flags 1
[RESULT] [597737.500208] action_1 gpup 50599 cpu_cores_count 0
[RESULT] [597737.500254] action_1 gpup 50599 simd_count 256
...
[RESULT] [597737.501603] action_1 gpup 50599 0 recommended_transfer_size 0
[RESULT] [597737.501626] action_1 gpup 50599 0 flags 1
[RESULT] [597737.501877] action_1 gpup 33367 cpu_cores_count 0
[RESULT] [597737.501921] action_1 gpup 33367 simd_count 256
...
[RESULT] [597737.503258] action_1 gpup 33367 0 recommended_transfer_size 0
[RESULT] [597737.503282] action_1 gpup 33367 0 flags 1
...

Example 2:

Consider action:

actions:
- name: action_1
  device: all
  module: gpup
  properties:
    simd_count:
    mem_banks_count:
    io_links_count:
    vendor_id:
    device_id:
    location_id:
    max_engine_clk_ccompute:
  io_links-properties:
    version_major:
    type:
    version_major:
    version_minor:
    node_from:
    node_to:
    recommended_transfer_size:
    flags:

This action explicitly lists some of the properties. Output for such configuration may be:

[RESULT] [597868.690637] action_1 gpup 3254 device_id 26720
[RESULT] [597868.690713] action_1 gpup 3254 io_links_count 1
[RESULT] [597868.690766] action_1 gpup 3254 location_id 8960
[RESULT] [597868.690819] action_1 gpup 3254 max_engine_clk_ccompute 2200
[RESULT] [597868.690862] action_1 gpup 3254 mem_banks_count 1
[RESULT] [597868.690903] action_1 gpup 3254 simd_count 256
[RESULT] [597868.690950] action_1 gpup 3254 vendor_id 4098
[RESULT] [597868.691029] action_1 gpup 3254 0 flags 1
[RESULT] [597868.691053] action_1 gpup 3254 0 node_from 4
[RESULT] [597868.691075] action_1 gpup 3254 0 node_to 1
[RESULT] [597868.691099] action_1 gpup 3254 0 recommended_transfer_size 0
[RESULT] [597868.691119] action_1 gpup 3254 0 type 2
[RESULT] [597868.691138] action_1 gpup 3254 0 version_major 0
[RESULT] [597868.691158] action_1 gpup 3254 0 version_minor 0
[RESULT] [597868.691425] action_1 gpup 50599 device_id 26720
[RESULT] [597868.691469] action_1 gpup 50599 io_links_count 1
[RESULT] [597868.691517] action_1 gpup 50599 location_id 17152
...
[RESULT] [597868.692159] action_1 gpup 33367 device_id 26720
[RESULT] [597868.692204] action_1 gpup 33367 io_links_count 1
[RESULT] [597868.692252] action_1 gpup 33367 location_id 25344
...
[RESULT] [597868.692619] action_1 gpup 33367 0 version_minor 0

Example 3:

Consider this action:

actions:
- name: action_1
  device: all
  module: gpup
  deviceid: 267
  properties:
    all:
  io_links-properties:
    all:

Action lists deviceid 267 which is not present in the system. Output for such configuration is:

RVS-GPUP: action: action_1  invalid 'deviceid' key value

GM Module#

The GPU monitor module can be used monitor and characterize the response of a GPU to different levels of use. This module is intended to run concurrently with other actions, and provides a ‘start’ and ‘stop’ configuration key to start the monitoring and then stop it after testing has completed. The module can also be configured with bounding box values for interested GPU parameters. If any of the GPU’s parameters exceed the bounding values on a specific GPU an INFO warning message will be printed to stdout while the bounding value is still exceeded.

Module Specific Keys#

Config Key Type Description
monitorBool If this this key is set to true, the GM module will start monitoring on specified devices. If this key is set to false, all other keys are ignored and monitoring of the specified device will be stopped.
metrics Collection of Structures, specifying the metric, if there are bounds and the bound values. The structures have the following format:\n{String, Bool, Integer, Integer} The set of metrics to monitor during the monitoring period. Example values are:\n{‘temp’, ‘true’, max_temp, min_temp}\n {‘clock’, ‘false’, max_clock, min_clock}\n {‘mem_clock’, ‘true’, max_mem_clock, min_mem_clock}\n {‘fan’, ‘true’, max_fan, min_fan}\n {‘power’, ‘true’, max_power, min_power}\n The set of upper bounds for each metric are specified as an integer. The units and values for each metric are:\n temp - degrees Celsius\n clock - MHz \n mem_clock - MHz \n fan - Integer between 0 and 255 \n power - Power in Watts
sample_intervalInteger If this key is specified metrics will be sampled at the given rate. The units for the sample_interval are milliseconds. The default value is 1000.
log_intervalInteger If this key is specified informational messages will be emitted at the given interval, providing the current values of all parameters specified. This parameter must be equal to or greater than the sample rate. If this value is not specified, no logging will occur.
terminateBool If the terminate key is true the GM monitor will terminate the RVS process when a bounds violation is encountered on any of the metrics specified.
forceBool If 'true' and terminate key is also 'true' the RVS process will terminate immediately. **Note:** this may cose resource leaks within GPUs.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
metric_valuesTime Series Collection of Result IntegersA collection of integers containing the result values for each of the metrics being monitored.
metric_violationsCollection of Result Integers A collection of integers containing the violation count for each of the metrics being monitored.
metric_averageCollection of Result Integers

When monitoring is started for a target GPU, a result message is logged with the following format:

[RESULT][<timestamp>][<action name>] gm <gpu id> started

In addition, an informational message is provided for each for each metric being monitored:

[INFO ][<timestamp>][<action name>] gm <gpu id> monitoring <metric> bounds min:<min_metric> max: <max_metric>

During the monitoring informational output regarding the metrics of the GPU will be sampled at every interval specified by the sample_rate key. If a bounding box violation is discovered during a sampling interval, a warning message is logged with the following format:

[INFO ][<timestamp>][<action name>] gm <gpu id> <metric> bounds violation <metric value>

If the log_interval value is set an information message for each metric is logged at every interval using the following format:

[INFO ][<timestamp>][<action name>] gm <gpu id> <metric> <metric_value>

When monitoring is stopped for a target GPU, a result message is logged with the following format:

[RESULT][<timestamp>][<action name>] gm <gpu id> gm stopped

The following messages, reporting the number of metric violations that were sampled over the duration of the monitoring and the average metric value is reported:

[RESULT][<timestamp>][<action name>] gm <gpu id> <metric> violations <metric_violations>
[RESULT][<timestamp>][<action name>] gm <gpu id> <metric> average <metric_average>

Examples#

Example 1:

Consider action:

actions:
- name: action_1
  module: gm
  device: all
  monitor: true
  metrics:
    temp: true 20 0
    fan: true 10 0
  duration: 5000
- name: another_action
...

This action will monitor temperature and fan speed for 5 seconds and then continue with the next action. Output for such configuration may be:

[RESULT] [694381.521373] [action_1] gm 33367 started
[INFO  ] [694381.531803] action_1 gm 33367  monitoring temp bounds min:0 max:20
[INFO  ] [694381.531817] action_1 gm 33367  monitoring temp bounds min:0 max:20
[INFO  ] [694381.531828] action_1 gm 33367  monitoring fan bounds min:0 max:10
[RESULT] [694381.521373] [action_1] gm 3254 started
[INFO  ] [694381.532257] action_1 gm 3254  monitoring temp bounds min:0 max:20
[INFO  ] [694381.532276] action_1 gm 3254  monitoring temp bounds min:0 max:20
[INFO  ] [694381.532293] action_1 gm 3254  monitoring fan bounds min:0 max:10
[RESULT] [694381.521373] [action_1] gm 50599 started
[INFO  ] [694381.534471] action_1 gm 50599  monitoring temp bounds min:0 max:20
[INFO  ] [694381.534487] action_1 gm 50599  monitoring temp bounds min:0 max:20
[INFO  ] [694381.534502] action_1 gm 50599  monitoring fan bounds min:0 max:10
[INFO  ] [694381.534623] action_1 gm 33367 temp  bounds violation 22C
[INFO  ] [694381.534822] action_1 gm 3254 temp  bounds violation 22C
[INFO  ] [694381.534946] action_1 gm 50599 temp  bounds violation 22C
[INFO  ] [694382.535329] action_1 gm 33367 temp  bounds violation 22C
...
[INFO  ] [694385.537777] action_1 gm 50599 temp  bounds violation 21C
[RESULT] [694386.538037] [action_1] gm 3254 stopped
[RESULT] [694386.538037] [action_1] gm 50599 stopped
[RESULT] [694386.538037] [action_1] gm 33367 stopped
[RESULT] [694386.521449] [action_1] gm 3254 temp violations 1
[RESULT] [694386.521449] [action_1] gm 3254 temp average 19C
[RESULT] [694386.521449] [action_1] gm 3254 fan violations 0
[RESULT] [694386.521449] [action_1] gm 3254 fan average 0%
[RESULT] [694386.521449] [action_1] gm 50599 temp violations 5
[RESULT] [694386.521449] [action_1] gm 50599 temp average 21C
[RESULT] [694386.521449] [action_1] gm 50599 fan violations 0
[RESULT] [694386.521449] [action_1] gm 50599 fan average 0%
[RESULT] [694386.521449] [action_1] gm 33367 temp violations 5
[RESULT] [694386.521449] [action_1] gm 33367 temp average 22C
[RESULT] [694386.521449] [action_1] gm 33367 fan violations 0
[RESULT] [694386.521449] [action_1] gm 33367 fan average 0%

Example 2:

Consider action:

actions:
- name: action_1
  module: gm
  device: all
  monitor: true
  metrics:
    temp: true 20 0
    fan: true 10 0
    power: true 100 0
  sample_interval: 1000
  log_interval: 1200
  terminate: false
  duration: 5000

This configuration is similar to that in Example 1 but has explicitly given values for sample_interval and log_interval. Output is similar to the previous one but averaging and the printout are performed at a different rate.

Example 3:

Consider action with syntax error (‘temp’ key is missing lower value):

actions:
- name: action_1
  module: gm
  device: 33367 50599
  monitor: true
  metrics:
    temp: true 20
    fan: true 10 0
    power: true 100 0
  sample_interval: 1000
  log_interval: 1200

Output for such configuration is:

RVS-GM: action: action_1 Wrong number of metric parameters

Example 4:

Consider action with logical error:

actions:
- name: action_1
  module: gm
  device: all
  monitor: true
  metrics:
    temp: false 20 0
    clock: true 1500 852
    power: true 100 0
  sample_interval: 5000
  log_interval: 4000
  duration: 8000

Output for such configuration is:

RVS-GM: action: action_1 Log interval has the lower value than the sample interval

PESM Module#

The PCIe State Monitor (PESM) tool is used to actively monitor the PCIe interconnect between the host platform and the GPU. The module registers “listener” on a target GPUs PCIe interconnect, and log a message whenever it detects a state change. The PESM is able to detect the following state changes:

  1. PCIe link speed changes

  2. GPU device power state changes

This module is intended to run concurrently with other actions, and provides a ‘start’ and ‘stop’ configuration key to start the monitoring and then stop it after testing has completed. For information on GPU power state monitoring please consult the 7.6. PCI Power Management Capability Structure, Gen 3 spec, page 601, device states D0-D3. For information on link status changes please consult the 7.8.8. Link Status Register (Offset 12h), Gen 3 spec, page 635.

Monitoring is performed by polling respective PCIe registers roughly every 1ms (one millisecond).

Module Specific Keys#

Config Key Type Description
monitorBoolThis this key is set to true, the PESM module will start monitoring on specified devices. If this key is set to false, all other keys are ignored and monitoring will be stopped for all devices.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
stateStringA string detailing the current power state of the GPU or the speed of the PCIe link.

When monitoring is started for a target GPU, a result message is logged with the following format:

[RESULT][<timestamp>][<action name>] pesm <gpu id> started

When monitoring is stopped for a target GPU, a result message is logged with the following format:

[RESULT][<timestamp>][<action name>] pesm all stopped

When monitoring is enabled, any detected state changes in link speed or GPU power state will generate the following informational messages:

[INFO ][<timestamp>][<action name>] pesm <gpu id> power state change <state>
[INFO ][<timestamp>][<action name>] pesm <gpu id> link speed change <state>

Examples#

Example 1

Here is a typical check utilizing PESM functionality:

actions:
- name: action_1
  device: all
  module: pesm
  monitor: true
- name: action_2
  device: 33367
  module: gst
  parallel: false
  count: 2
  wait: 100
  duration: 18000
  ramp_interval: 7000
  log_interval: 1000
  max_violations: 1
  copy_matrix: false
  target_stress: 5000
  tolerance: 0.07
  matrix_size: 5760
- name: action_3
  device: all
  module: pesm
  monitor: false
  • action_1 will initiate monitoring on all devices by setting key monitor to true\n

  • action_2 will start GPU stress test

  • action_3 will stop monitoring

If executed like this:

sudo rvs -c conf/pesm8.conf -d 3

output similar to this one can be produced:

[RESULT] [497544.637462] [action_1] pesm all started
[INFO  ] [497544.648299] [action_1] pesm 33367 link speed change 8 GT/s
[INFO  ] [497544.648299] [action_1] pesm 33367 power state change D0
[INFO  ] [497544.648733] [action_1] pesm 3254 link speed change 8 GT/s
[INFO  ] [497544.648733] [action_1] pesm 3254 power state change D0
[INFO  ] [497544.650413] [action_1] pesm 50599 link speed change 8 GT/s
[INFO  ] [497544.650413] [action_1] pesm 50599 power state change D0
[INFO  ] [497545.170392] [action_2] gst 33367 start 5000.000000 copy matrix:false
[INFO  ] [497547.36602 ] [action_2] gst 33367 Gflops 6478.066983
[INFO  ] [497548.69221 ] [action_2] gst 33367 target achieved 5000.000000
[INFO  ] [497549.101219] [action_2] gst 33367 Gflops 5189.993529
[INFO  ] [497550.132376] [action_2] gst 33367 Gflops 5189.993529
...
[INFO  ] [497563.569370] [action_2] gst 33367 Gflops 5174.935520
[RESULT] [497564.86904 ] [action_2] gst 33367 Gflop: 6478.066983 flops_per_op: 382.205952x1e9 bytes_copied_per_op: 398131200 try_ops_per_sec: 13.081952 pass: TRUE
[INFO  ] [497564.220311] [action_2] gst 33367 start 5000.000000 copy matrix:false
[INFO  ] [497566.70585 ] [action_2] gst 33367 Gflops 6521.049418
[INFO  ] [497567.99929 ] [action_2] gst 33367 target achieved 5000.000000
[INFO  ] [497568.143096] [action_2] gst 33367 Gflops 5130.281235
...
[INFO  ] [497582.683893] [action_2] gst 33367 Gflops 5135.204729
[RESULT] [497583.130945] [action_2] gst 33367 Gflop: 6521.049418 flops_per_op: 382.205952x1e9 bytes_copied_per_op: 398131200 try_ops_per_sec: 13.081952 pass: TRUE
[RESULT] [497583.155470] [action_3] pesm all stopped

Example 2:

Consider this file:

actions:
- name: act1
  device: all
  deviceid: xxx
  module: pesm
  monitor: true

This file has and invalid entry in deviceid key. If execute, an error will be reported:

RVS-PESM: action: act1  invalide 'deviceid' key value: xxx

RCQT Module#

This ‘module’ is actually a set of feature checks that target and qualify the configuration of the platform. Many of the checks can be done manually using the operating systems command line tools and general knowledge about ROCm’s requirements. The purpose of the RCQT modules is to provide an extensible, OS independent and scriptable interface capable for performing the configuration checks required for ROCm support. The checks in this module do not target a specific device (instead the underlying platform is targeted), and any device or device id keys specified will be ignored. Iteration keys, i.e. count, wait and duration, are also ignored. \n\n One RCQT action can perform only one check at the time. Checks are decoded in this order:\n

  • If ‘package’ key is detected, packaging check will be performed

  • If ‘user’ key is detected, user check will be performed

  • If ‘os_versions’ and ‘kernel_versions’ keys are detected, OS check will be performed

  • If ‘soname’, ‘arch’ and ‘ldpath’ keys are detected, linker/loader check will be performed

  • If ‘file’ key is detected, file check will be performed

All other keys not pertinent to the detected action are ignored.

Packaging Check#

This feature is used to check installed packages on the system. It provides checks for installed packages and the currently available package versions, if applicable.

Packaging Check Specific Keys#

Input keys are described in the table below:

Config Key Type Description
packageString Specifies the package to check. This key is required.
versionString This is an optional key specifying a package version. If it is provided, the tool will check if the version is installed, failing otherwise. If it is not provided any version matching the package name will result in success.

Output#

Output keys are described in the table below:

Output Key Type Description
installedBool If the test has passed, the output will be true. Otherwise it will be false.

The check will emit a result message with the following format:

[RESULT][<timestamp>][<action name>] rcqt packagecheck <package> <installed>

The package name will include the version of the package if the version key is specified. The installed output value will either be true or false depending on if the package is installed or not.

Examples#

Example 1:

In this example, given package does not exist.

actions:
- name: action_1
  module: rcqt
  package: zip12345

The output for such configuration is:

[RESULT] [500022.877512] [action_1] rcqt packagecheck zip12345 FALSE

Example 2:

In this example, version of the given package is incorrect.

actions:
- name: action_1
  module: rcqt
  package: zip
  version: 3.0-11****

The output for such configuration is:

[RESULT] [500123.480561] [action_1] rcqt packagecheck zip FALSE

Example 3:

In this example, given package exists.

actions:
- name: action_1
  module: rcqt
  package: zip

The output for such configuration is:

[RESULT] [500329.824495] [action_1] rcqt packagecheck zip TRUE

Example 4:

In this example, given package exists and its version is correct.

actions:
- name: action_1
  module: rcqt
  package: zip
  version: 3.0-11

The output for such configuration is:

[RESULT] [500595.859025] [action_1] rcqt packagecheck zip TRUE

User Check#

This feature checks for the existence of a user and the user’s group membership.

User Check Specific Keys#

Input keys are described in the table below:

Config Key Type Description
userString Specifies the user name to check. This key is required.
groupsCollection of Strings This is an optional key specifying a collection of groups the user should belong to. The user’s membership in each group will be checked.

Output#

Output keys are described in the table below:

Output Key Type Description
existsBool This value is true if the user exists.
membersCollection of Bools This value is true if the user is a member of the specified group.

The status of the user’s existence is provided in a message with the following format:

[RESULT][<timestamp>][<action name>] rcqt usercheck <user> <exists>

For each group in the list, a result message with the following format will be generated:

[RESULT][<timestamp>][<action name>] rcqt usercheck <user> <group> <member>

If the user doesn’t exist no group checks will take place.

Examples#

Example 1:

In this example, given user does not exist.

actions:
- name: action_1
  device: all
  module: rcqt
  user: jdoe
  group: sudo,video

The output for such configuration is:

[RESULT] [496559.219160] [action_1] rcqt usercheck jdoe false

Group check is not performed.

Example 2:

In this example, group rvs does not exist.

actions:
- name: action_1
  device: all
  module: rcqt
  user: jovanbhdl
  group: rvs,video

The output for such configuration is:

[RESULT] [496984.993394] [action_1] rcqt usercheck jovanbhdl true
[ERROR ] [496984.993535] [action_1] rcqt usercheck group rvs doesn't exist
[RESULT] [496984.993578] [action_1] rcqt usercheck jovanbhdl video true

Example 3:

In this example, given user exists and belongs to given groups.

actions:
- name: action_1
  device: all
  module: rcqt
  user: jovanbhdl
  group: sudo,video

The output for such configuration is:

[RESULT] [497361.361045] [action_1] rcqt usercheck jovanbhdl true
[RESULT] [497361.361168] [action_1] rcqt usercheck jovanbhdl sudo true
[RESULT] [497361.361209] [action_1] rcqt usercheck jovanbhdl video true

File/device Check#

This feature checks for the existence of a file, its owner, group, permissions and type. The primary purpose of this module is to check that the device interfaces for the driver and the kfd are available, but it can also be used to check for the existence of important configuration files, libraries and executables.

File/device Check Specific Keys#

Input keys are described in the table below:

Config Key Type Description
fileString The value of this key should satisfy the file name limitations of the target OS and specifies the file to check. This key is required.
ownerString The expected owner of the file. If this key is specified ownership is tested.
groupString If this key is specified, group ownership is tested.
permissionInteger If this key is specified, the permissions on the file are tested. The permissions are expected to match the permission value given.
typeInteger If this key is specified the file type is checked.
existsBool If this key is specified and set to false all optional parameters will be ignored and a check will be made to make sure the file does not exist. The default value for this key is true.

Output#

Output keys are described in the table below:

Output Key Type Description
ownerBool True if the correct user owns the file.
groupBool True if the correct group owns the file.
permissionBool True if the file has the correct permissions.
typeBool True if the file is of the right type.
existsBool True if the file exists and the ‘exists’ config key is true. True if the file does not exist and the ‘exists’ key if false.

If the ‘exists’ key is true a set of messages, one for each stat check, will be generated with the following format:

[RESULT][<timestamp>][<action name>] rcqt filecheck <config key> <matching output key>

If the ‘exists’ key is false the format of the message will be:

[RESULT][<timestamp>][<action name>] rcqt filecheck <file> DNE <exists>

Examples#

Example 1:

In this example, config key exists is set to true by default and file really exists so parameters are tested. Permission number 644 equals to rw-r–r– and type number 40 indicates that it is a folder.

rcqt_fc4.conf :

actions:
- name: action_1
  device: all
  module: rcqt
  file: /work/mvisekrunahdl/ROCmValidationSuite/rcqt.so/src
  owner: mvisekrunahdl
  group: mvisekrunahdl
  permission: 664
  type: 40

Output from running this action:

[RESULT] [240384.678074] [action_1] rcqt filecheck mvisekrunahdl owner:true
[RESULT] [240384.678214] [action_1] rcqt filecheck mvisekrunahdl group:true
[RESULT] [240384.678250] [action_1] rcqt filecheck 664 permission:true
[RESULT] [240384.678275] [action_1] rcqt filecheck 100 type:true

Example 2:

In this example, config key exists is set to false, but file actually exists so parameters are not tested.

rcqt_fc1.conf:

actions:
- name: action_1
  device: all
  module: rcqt
  file: /work/mvisekrunahdl/ROCmValidationSuite/src
  owner: root
  permission: 644
  type: 40
  exists: false

The output for such configuration is:

[RESULT] [240188.150386] [action_1] rcqt filecheck /work/mvisekrunahdl/ROCmValidationSuite/src DNE false

Example 3:

In this example, config key exists is true by default and file really exists. Config key group, permission and type are not specified so only ownership is tested.

rcqt_fc2.conf:

actions:
- name: action_1
  device: all
  module: rcqt
  file: /work/mvisekrunahdl/build/test.txt
  owner: root

The output for such configuration is:

[RESULT] [240253.957738] [action_1] rcqt filecheck root owner:true

Example 4:

In this example, config key exists is true by default, but given file does not exist.

rcqt_fc3.conf:

actions:
- name: action_1
  device: all
  module: rcqt
  file: /work/mvisekrunahdl/ROCmValidationSuite/rcqt.so/src/tst
  owner: mvisekrunahdl
  group: mvisekrunahdl
  permission: 664
  type: 100

The output for such configuration is:

[ERROR ] [240277.355553] [action_1] rcqt File is not found

Kernel compatibility Check#

The rcqt-kernelcheck module determines the version of the operating system and the kernel installed on the platform and compares the values against the list of supported values.

Kernel compatibility Check Specific Keys#

Input keys are described in the table below:

Config Key Type Description
os_versionsCollection of Strings A collection of strings corresponding to operating systems names, i.e. {“Ubuntu 16.04.3 LTS”, “Centos 7.4”, etc.}
kernel_versionsCollection of Strings A collection of strings corresponding to kernel version names, i.e. {“4.4.0-116-generic”, “4.13.0-36-generic”, etc.}

Output#

Output keys are described in the table below:

Output Key Type Description
osString The actual OS installed on the system.
kernelString The actual kernel version installed on the system.
passBool True if the actual os version and kernel version match any value provided in the collection.

If the detected versions of the operating system and the kernel version match any of the supported values the pass output key will be true. Otherwise it will be false. The result message will contain the actual os version and the kernel version regardless of where the check passed or failed.

[RESULT][<timestamp>][<action name>] rcqt kernelcheck <os version> <kernel version> <pass>

Examples#

Example 1:

In this example, given kernel version is incorrect.

actions:
- name: action_1
  device: all
  module: rcqt
  os_version: Ubuntu 16.04.5 LTS
  kernel_version: 4.4.0-116-generic-wrong

The output for such configuration is:

[RESULT] [498398.774182] [action_1] rcqt kernelcheck Ubuntu 16.04.5 LTS 4.18.0-rc1-kfd-compute-roc-master-8874 fail

Example 2

In this example, given os version and kernel verison are the correct ones.

actions:
- name: action_1
  device: all
  module: rcqt
  os_version: Ubuntu 16.04.5 LTS
  kernel_version: 4.18.0-rc1-kfd-compute-roc-master-8874

The output for such configuration is:

[RESULT] [515924.695932] [action_1] rcqt kernelcheck Ubuntu 16.04.5 LTS 4.18.0-rc1-kfd-compute-roc-master-8874 pass

Linker/Loader Check#

This feature checks that a search by the linker/loader for a library finds the correct version in the correct location. The check should include a SONAME version of the library, the expected location and the architecture of the library.

Linker/Loader Check Specific Keys#

Input keys are described in the table below:

Config Key Type Description
sonameString This is the SONAME of the library for the check. An SONAME library contains the major version of the library in question.
archString This value qualifies the architecture expected for the library.
ldpathString This is the fully qualified path where the library is expected to be located.

Output#

Output keys are described in the table below:

Output Key Type Description
archString The actual architecture found for the file, or NA if it wasn’t found.
pathString The actual path the linker is looking for the file at, or “not found” if the file isn’t found.
passBool True if the linker/loader is looking for the file in the correct place with the correctly specified architecture.

If the linker/loader search path looks for the soname version of the library, qualified by arch, at the directory specified the test will pass. Otherwise it will fail. The output message has the following format:

[RESULT][<timestamp>][<action name>] rcqt ldconfigcheck <soname> <arch> <path> <pass>

Examples#

Example 1:

Consider this action:

actions:
- name: action_1
  device: all
  module: rcqt
  soname: librcqt.so.0.0.3fail
  arch: i386:x86-64
  ldpath: /work/jovanbhdl/build/bin

The test will fail because the file given is not found on the specified path:

[RESULT] [587042.789384] [action_1] rcqt ldconfigcheck librcqt.so.0.0.3fail i386:x86-64 /work/jovanbhdl/build/bin false

Example 2:

Consider this action:

actions:
- name: action_1
  device: all
  module: rcqt
  soname: librcqt.so.0.0.16
  arch: i386:x86-64
  ldpath: /work/jovanbhdl/build/bin

The test will pass and will output the message:

[RESULT] [587047.395787] [action_1] rcqt ldconfigcheck librcqt.so.0.0.16 i386:x86-64 /work/jovanbhdl/build/bin true

PEQT Module#

PCI Express Qualification Tool module targets and qualifies the configuration of the platforms PCIe connections to the GPUs. The purpose of the PEQT module is to provide an extensible, OS independent and scriptable interface capable of performing the PCIe interconnect configuration checks required for ROCm support of GPUs. This information can be obtained through the sysfs PCIe interface or by using the PCIe development libraries to extract values from various PCIe control, status and capabilities registers. These registers are specified in the PCI Express Base Specification, Revision 3. Iteration keys, i.e. count, wait and duration will be ignored for actions using the PEQT module.

Module Specific Keys#

Module specific output keys are described in the table below:

Config Key Type Description
capabilityCollection of Structures with the following format:\n{String,String} The PCIe capability key contains a collection of structures that specify which PCIe capability to check and the expected value of the capability. A check structure must contain the PCIe capability value, but an expected value may be omitted. The value of all valid capabilities that are a part of this collection will be entered into the capability_value field. Possible capabilities, and their value types are:\n\n link_cap_max_speed\n link_cap_max_width\n link_stat_cur_speed\n link_stat_neg_width\n slot_pwr_limit_value\n slot_physical_num\n bus_id\n atomic_op_32_completer\n atomic_op_64_completer\n atomic_op_128_CAS_completer\n atomic_op_routing\n dev_serial_num\n kernel_driver\n pwr_base_pwr\n pwr_rail_type\n device_id\n vendor_id\n\n

The expected value String is a regular expression that is used to check the actual value of the capability.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
capability_valueCollection of Strings For each of the capabilities specified in the capability key, the actual value of the capability will be returned, represented as a String.
passString 'true' if all of the properties match the values given, 'false' otherwise.

The qualification check queries the specified PCIe capabilities and properties and checks that their actual values satisfy the regular expression provided in the ‘expected value’ field for that capability. The pass output key will be true and the test will pass if all of the properties match the values given. After the check is finished, the following informational messages will be generated:

[INFO  ][<timestamp>][<action name>] peqt <capability> <capability_value>
[RESULT][<timestamp>][<action name>] peqt <pass>

For details regarding each of the capabilities and current values consult the chapters in the PCI Express Base Specification, Revision 3.

Examples#

Example 1:

A regular PEQT configuration file looks like this:

actions:
- name: pcie_act_1
  module: peqt
  capability:
    link_cap_max_speed:
    link_cap_max_width:
    link_stat_cur_speed:
    link_stat_neg_width:
    slot_pwr_limit_value:
    slot_physical_num:
    device_id:
    vendor_id:
    kernel_driver:
    dev_serial_num:
    D0_Maximum_Power_12V:
    D0_Maximum_Power_3_3V:
    D0_Sustained_Power_12V:
    D0_Sustained_Power_3_3V:
    atomic_op_routing:
    atomic_op_32_completer:
    atomic_op_64_completer:
    atomic_op_128_CAS_completer:
  device: all

Please note:

  • when setting the ‘device’ configuration key to ‘all’, the RVS will detect all the AMD compatible GPUs and run the test on all of them

  • there are no regular expression for this .conf file, therefore RVS will report TRUE if at least one AMD compatible GPU is registered within the system. Otherwise it will report FALSE.

Please note that the Power Budgeting capability is a dynamic one, having the following form:

<PM_State>_<Type>_<Power rail>

where:

PM_State = D0/D1/D2/D3
Type=PMEAux/Auxiliary/Idle/Sustained/Maximum
PowerRail = Power_12V/Power_3_3V/Power_1_5V_1_8V/Thermal

When the RVS tool runs against such a configuration file, it will query for the all the PCIe capabilities specified under the capability list (and log the corresponding values) for all the AMD compatible GPUs. For those PCIe capabilities that are not supported by the HW platform were the RVS is running, a “NOT SUPPORTED” message will be logged.

The output for such a configuration file may look like this:

[INFO ] [177628.401176] pcie_act_1 peqt D0_Maximum_Power_12V NOT SUPPORTED
[INFO ] [177628.401229] pcie_act_1 peqt D0_Maximum_Power_3_3V NOT SUPPORTED
[INFO ] [177628.401248] pcie_act_1 peqt D0_Sustained_Power_12V NOT SUPPORTED
[INFO ] [177628.401269] pcie_act_1 peqt D0_Sustained_Power_3_3V NOT SUPPORTED
[INFO ] [177628.401282] pcie_act_1 peqt atomic_op_128_CAS_completer FALSE
[INFO ] [177628.401291] pcie_act_1 peqt atomic_op_32_completer FALSE
[INFO ] [177628.401303] pcie_act_1 peqt atomic_op_64_completer FALSE
[INFO ] [177628.401311] pcie_act_1 peqt atomic_op_routing TRUE
[INFO ] [177628.401317] pcie_act_1 peqt dev_serial_num NOT SUPPORTED
[INFO ] [177628.401323] pcie_act_1 peqt device_id 26720
[INFO ] [177628.401334] pcie_act_1 peqt kernel_driver amdgpu
[INFO ] [177628.401342] pcie_act_1 peqt link_cap_max_speed 8 GT/s
[INFO ] [177628.401352] pcie_act_1 peqt link_cap_max_width x16
[INFO ] [177628.401359] pcie_act_1 peqt link_stat_cur_speed 8 GT/s
[INFO ] [177628.401367] pcie_act_1 peqt link_stat_neg_width x16
[INFO ] [177628.401375] pcie_act_1 peqt slot_physical_num #0
[INFO ] [177628.401396] pcie_act_1 peqt slot_pwr_limit_value 0.000W
[INFO ] [177628.401402] pcie_act_1 peqt vendor_id 4098
[INFO ] [177628.401656] pcie_act_1 peqt D0_Maximum_Power_12V NOT SUPPORTED
[INFO ] [177628.401675] pcie_act_1 peqt D0_Maximum_Power_3_3V NOT SUPPORTED
[INFO ] [177628.401692] pcie_act_1 peqt D0_Sustained_Power_12V NOT SUPPORTED
[INFO ] [177628.401709] pcie_act_1 peqt D0_Sustained_Power_3_3V NOT SUPPORTED
[INFO ] [177628.401719] pcie_act_1 peqt atomic_op_128_CAS_completer FALSE
[INFO ] [177628.401728] pcie_act_1 peqt atomic_op_32_completer FALSE
[INFO ] [177628.401736] pcie_act_1 peqt atomic_op_64_completer FALSE
[INFO ] [177628.401745] pcie_act_1 peqt atomic_op_routing TRUE
[INFO ] [177628.401750] pcie_act_1 peqt dev_serial_num NOT SUPPORTED
[INFO ] [177628.401757] pcie_act_1 peqt device_id 26720
[INFO ] [177628.401771] pcie_act_1 peqt kernel_driver amdgpu
[INFO ] [177628.401781] pcie_act_1 peqt link_cap_max_speed 8 GT/s
[INFO ] [177628.401788] pcie_act_1 peqt link_cap_max_width x16
[INFO ] [177628.401794] pcie_act_1 peqt link_stat_cur_speed 8 GT/s
[INFO ] [177628.401800] pcie_act_1 peqt link_stat_neg_width x16
[INFO ] [177628.401806] pcie_act_1 peqt slot_physical_num #0
[INFO ] [177628.401814] pcie_act_1 peqt slot_pwr_limit_value 0.000W
[INFO ] [177628.401819] pcie_act_1 peqt vendor_id 4098
[RESULT] [177628.403781] pcie_act_1 peqt TRUE

Example 2:

Another example of a configuration file, which queries for a smaller subset of PCIe capabilities but adds regular expressions check, is given below

actions:
- name: pcie_act_1
  module: peqt
  capability:
    link_cap_max_speed: '^(2\.5 GT\/s|5 GT\/s|8 GT\/s)$'
    link_cap_max_width:
    link_stat_cur_speed: '^(2\.5 GT\/s|5 GT\/s|8 GT\/s)$'
    link_stat_neg_width:
    slot_pwr_limit_value: '[a-b][d-'
    slot_physical_num:
    device_id:
    vendor_id:
    kernel_driver:
  device: all

For this example, the expected PEQT check result is TRUE if:

  • at least one AMD compatible GPU is registered within the system and:

  • all <link_cap_max_speed> values for all AMD compatible GPUs match the given regular expression and

  • all <link_stat_cur_speed> values for all AMD compatible GPUs match the given regular expression

Please note that the <slot_pwr_limit_value> regular expression is not valid and will be skipped without affecting the PEQT module’s check RESULT (however, an error will be logged out)

Example 3:

Another example with even more regular expressions is given below. The expected PEQT check result is TRUE if at least one AMD compatible GPU having the ID 3254 or 33367 is registered within the system and all the PCIe capabilities values match their corresponding regular expressions.

actions:
- name: pcie_act_1
  module: peqt
  deviceid: 26720
  capability:
    link_cap_max_speed: '^(2\.5 GT\/s|5 GT\/s|8 GT\/s)$'
    link_cap_max_width: ^(x8|x16)$
    link_stat_cur_speed: '^(8 GT\/s)$'
    link_stat_neg_width: ^(x8|x16)$
    kernel_driver: ^amdgpu$
    atomic_op_routing: ^((TRUE|FALSE){1})$
    atomic_op_32_completer: ^((TRUE|FALSE){1})$
    atomic_op_64_completer: ^((TRUE|FALSE){1})$
    atomic_op_128_CAS_completer: ^((TRUE|FALSE){1})$
  device: 3254 33367

SMQT Module#

The GPU SBIOS mapping qualification tool is designed to verify that a platform’s SBIOS has satisfied the BAR mapping requirements for VDI and Radeon Instinct products for ROCm support. These are the current BAR requirements:\n\n

BAR 1: GPU Frame Buffer BAR – In this example it happens to be 256M, but typically this will be size of the GPU memory (typically 4GB+). This BAR has to be placed < 2^40 to allow peer- to-peer access from other GFX8 AMD GPUs. For GFX9 (Vega GPU) the BAR has to be placed < 2^44 to allow peer-to-peer access from other GFX9 AMD GPUs.\n\n

BAR 2: Doorbell BAR – The size of the BAR is typically will be < 10MB (currently fixed at 2MB) for this generation GPUs. This BAR has to be placed < 2^40 to allow peer-to-peer access from other current generation AMD GPUs.\n\n BAR 3: IO BAR - This is for legacy VGA and boot device support, but since this the GPUs in this project are not VGA devices (headless), this is not a concern even if the SBIOS does not setup.\n\n

BAR 4: MMIO BAR – This is required for the AMD Driver SW to access the configuration registers. Since the reminder of the BAR available is only 1 DWORD (32bit), this is placed < 4GB. This is fixed at 256KB.\n\n

BAR 5: Expansion ROM – This is required for the AMD Driver SW to access the GPU’s video-BIOS. This is currently fixed at 128KB.\n\n

Refer to the ROCm Use of Advanced PCIe Features and Overview of How BAR Memory is Used In ROCm Enabled System web page for more information about how BAR memory is initialized by VDI and Radeon products. Iteration keys, i.e. count, wait and duration will be ignored.

Module Specific Keys#

Module specific output keys are described in the table below:

Config Key Type Description
bar1_req_sizeInteger This is an integer specifying the required size of the BAR1 frame buffer region.
bar1_base_addr_minInteger This is an integer specifying the minimum value the BAR1 base address can be.
bar1_base_addr_maxInteger This is an integer specifying the maximum value the BAR1 base address can be.
bar2_req_sizeInteger This is an integer specifying the required size of the BAR2 frame buffer region.
bar2_base_addr_minInteger This is an integer specifying the minimum value the BAR2 base address can be.
bar2_base_addr_maxInteger This is an integer specifying the maximum value the BAR2 base address can be.
bar4_req_sizeInteger This is an integer specifying the required size of the BAR4 frame buffer region.
bar4_base_addr_minInteger This is an integer specifying the minimum value the BAR4 base address can be.
bar4_base_addr_maxInteger This is an integer specifying the maximum value the BAR4 base address can be.
bar5_req_sizeInteger This is an integer specifying the required size of the BAR5 frame buffer region.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
bar1_sizeIntegerThe actual size of BAR1.
bar1_base_addrIntegerThe actual base address of BAR1 memory.
bar2_sizeIntegerThe actual size of BAR2.
bar2_base_addrIntegerThe actual base address of BAR2 memory.
bar4_sizeIntegerThe actual size of BAR4.
bar4_base_addrIntegerThe actual base address of BAR4 memory.
bar5_sizeIntegerThe actual size of BAR5.
passString 'true' if all of the properties match the values given, 'false' otherwise.

The qualification check will query the specified bar properties and check that they satisfy the give parameters. The pass output key will be true and the test will pass if all of the BAR properties satisfy the constraints. After the check is finished, the following informational messages will be generated:

[INFO  ][<timestamp>][<action name>] smqt bar1_size <bar1_size>
[INFO  ][<timestamp>][<action name>] smqt bar1_base_addr <bar1_base_addr>
[INFO  ][<timestamp>][<action name>] smqt bar2_size <bar2_size>
[INFO  ][<timestamp>][<action name>] smqt bar2_base_addr <bar2_base_addr>
[INFO  ][<timestamp>][<action name>] smqt bar4_size <bar4_size>
[INFO  ][<timestamp>][<action name>] smqt bar4_base_addr <bar4_base_addr>
[INFO  ][<timestamp>][<action name>] smqt bar5_size <bar5_size>
[RESULT][<timestamp>][<action name>] smqt <pass>

Examples#

Example 1:

Consider this file (sizes are in bytes):

actions:
- name: action_1
  device: all
  module: smqt
  bar1_req_size: 17179869184
  bar1_base_addr_min: 0
  bar1_base_addr_max: 17592168044416
  bar2_req_size: 2097152
  bar2_base_addr_min: 0
  bar2_base_addr_max: 1099511627776
  bar4_req_size: 262144
  bar4_base_addr_min: 0
  bar4_base_addr_max: 17592168044416
  bar5_req_size: 131072

Results for three GPUs are:

[INFO  ] [257936.568768] [action_1]  smqt bar1_size      17179869184 (16.00 GB)
[INFO  ] [257936.568768] [action_1]  smqt bar1_base_addr 13C0000000C
[INFO  ] [257936.568768] [action_1]  smqt bar2_size      2097152 (2.00 MB)
[INFO  ] [257936.568768] [action_1]  smqt bar2_base_addr 13B0000000C
[INFO  ] [257936.568768] [action_1]  smqt bar4_size      524288 (512.00 KB)
[INFO  ] [257936.568768] [action_1]  smqt bar4_base_addr E4B00000
[INFO  ] [257936.568768] [action_1]  smqt bar5_size      0 (0.00 B)
[RESULT] [257936.568920] [action_1]  smqt fail
[INFO  ] [257936.569234] [action_1]  smqt bar1_size      17179869184 (16.00 GB)
[INFO  ] [257936.569234] [action_1]  smqt bar1_base_addr 1A00000000C
[INFO  ] [257936.569234] [action_1]  smqt bar2_size      2097152 (2.00 MB)
[INFO  ] [257936.569234] [action_1]  smqt bar2_base_addr 19F0000000C
[INFO  ] [257936.569234] [action_1]  smqt bar4_size      524288 (512.00 KB)
[INFO  ] [257936.569234] [action_1]  smqt bar4_base_addr E9900000
[INFO  ] [257936.569234] [action_1]  smqt bar5_size      0 (0.00 B)
[RESULT] [257936.569281] [action_1]  smqt fail
[INFO  ] [257936.570798] [action_1]  smqt bar1_size      17179869184 (16.00 GB)
[INFO  ] [257936.570798] [action_1]  smqt bar1_base_addr 16C0000000C
[INFO  ] [257936.570798] [action_1]  smqt bar2_size      2097152 (2.00 MB)
[INFO  ] [257936.570798] [action_1]  smqt bar2_base_addr 1710000000C
[INFO  ] [257936.570798] [action_1]  smqt bar4_size      524288 (512.00 KB)
[INFO  ] [257936.570798] [action_1]  smqt bar4_base_addr E7300000
[INFO  ] [257936.570798] [action_1]  smqt bar5_size      0 (0.00 B)
[RESULT] [257936.570837] [action_1]  smqt fail

In this example, BAR sizes reported by GPUs match those listed in configuration key except for the BAR5, hence the test fails.

PBQT Module#

The P2P Qualification Tool is designed to provide the list of all GPUs that support P2P and characterize the P2P links between peers. In addition to testing for P2P compatibility, this test will perform a peer-to-peer throughput test between all unique P2P pairs for performance evaluation. These are known as device-to-device transfers, and can be either uni-directional or bi-directional. The average bandwidth obtained is reported to help debug low bandwidth issues.

Module Specific Keys#

Config Key Type Description
peersCollection of Strings This is a required key, and specifies the set of GPU(s) considered being peers of the GPU specified in the action. If ‘all’ is specified, all other GPU(s) on the system will be considered peers. Otherwise only the GPU ids specified in the list will be considered.
peer_deviceidInteger This is an optional parameter, but if specified it restricts the peers list to a specific device type corresponding to the deviceid.
test_bandwidthBool If this key is set to true the P2P bandwidth benchmark will run if a pair of devices pass the P2P check.
bidirectionalBool This option is only used if test_bandwidth key is true. This specifies the type of transfer to run:\n - true – Do a bidirectional transfer test\n - false – Do a unidirectional transfer test from one node to another.
parallelBool This option is only used if the test_bandwidth key is true.\n - true – Run all test transfers in parallel.\n - false – Run test transfers one by one.
durationInteger This option is only used if test_bandwidth is true. This key specifies the duration a transfer test should run, given in milliseconds. If this key is not specified, the default value is 10000 (10 seconds).
log_intervalInteger This option is only used if test_bandwidth is true. This is a positive integer, given in milliseconds, that specifies an interval over which the moving average of the bandwidth will be calculated and logged. The default value is 1000 (1 second). It must be smaller than the duration key.\n if this key is 0 (zero), results are displayed as soon as the test transfer is completed.
block_sizeCollection of Integers Optional. Defines list of block sizes to be used in transfer tests.\n If "all" or missing list of block sizes used in rocm_bandwidth_test is used: - 1 * 1024 - 2 * 1024 - 4 * 1024 - 8 * 1024 - 16 * 1024 - 32 * 1024 - 64 * 1024 - 128 * 1024 - 256 * 1024 - 512 * 1024 - 1 * 1024 * 1024 - 2 * 1024 * 1024 - 4 * 1024 * 1024 - 8 * 1024 * 1024 - 16 * 1024 * 1024 - 32 * 1024 * 1024 - 64 * 1024 * 1024 - 128 * 1024 * 1024 - 256 * 1024 * 1024 - 512 * 1024 * 1024
b2b_block_sizeInteger This option is only used if both 'test_bandwidth' and 'parallel' keys are true. This is a positive integer indicating size in Bytes of a data block to be transferred continuously ("back-to-back") for the duration of one test pass. If the key is not present, ordinary transfers with size indicated in 'block_size' key will be performed.
link_typeInteger This is a positive integer indicating type of link to be included in bandwidth test. Numbering follows that listed in **hsa\_amd\_link\_info\_type\_t** in **hsa\_ext\_amd.h** file.

Please note that suitable values for log_interval and duration depend on your system.

  • log_interval, in sequential mode, should be long enough to allow all transfer tests to finish at lest once or “(pending)” and “(*)” will be displayed (see below). Number of transfers depends on number of peer NUMA nodes in your system. In parallel mode, it should be roughly 1.5 times the duration of single longest individual test.

  • duration, regardless of mode should be at least, 4 * log_interval.

You may obtain indication of how long single transfer between two NUMA nodes take by running test with “-d 4” switch and observing DEBUG messages for transfer start/finish. An output may look like this:

[DEBUG ] [183940.634118] [action_1] pbqt transfer 6 5 start
[DEBUG ] [183941.311671] [action_1] pbqt transfer 6 5 finish
[DEBUG ] [183941.312746] [action_1] pbqt transfer 4 5 start
[DEBUG ] [183941.990174] [action_1] pbqt transfer 4 5 finish
[DEBUG ] [183941.991244] [action_1] pbqt transfer 4 6 start
[DEBUG ] [183942.668687] [action_1] pbqt transfer 4 6 finish
[DEBUG ] [183942.669756] [action_1] pbqt transfer 5 4 start
[DEBUG ] [183943.340957] [action_1] pbqt transfer 5 4 finish
[DEBUG ] [183943.342037] [action_1] pbqt transfer 5 6 start
[DEBUG ] [183944.17957 ] [action_1] pbqt transfer 5 6 finish
[DEBUG ] [183944.19032 ] [action_1] pbqt transfer 6 4 start
[DEBUG ] [183944.700868] [action_1] pbqt transfer 6 4 finish

From this printout, it can be concluded that single transfer takes on average 800ms. Values for log_interval and duration should be set accordingly.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
p2p_resultBool Indicates if the gpu and the specified peer have P2P capabilities. If this quantity is true, the GPU pair tested has p2p capabilities. If false, they are not peers.
distanceInteger NUMA distance for these two peers
hop_typeString Link type for each link hop (e.g., PCIe, HyperTransport, QPI, ...)
hop_distanceInteger NUMA distance for this particular hop
transfer_idString String with format "/" where - transfer_index - is number, starting from 1, for each device-peer combination - transfer_number - is total number of device-peer combinations
interval_bandwidthFloat The average bandwidth of a p2p transfer, during the log_interval time period.\n This field may also take values: - (pending) - this means that no measurement has taken place yet. - xxxGBps (*) - this means no measurement within current log_interval but average from previous measurements is displayed.
bandwidthFloat The average bandwidth of a p2p transfer, averaged over the entire test duration of the interval. This field may also take value: - (not measured) - this means no test transfer completed for those peers. You may need to increase test duration.
durationFloat Cumulative duration of all transfers between the two particular nodes

If the value of test_bandwidth key is false, the tool will only try to determine if the GPU(s) in the peers key are P2P to the action’s GPU. In this case the bidirectional and log_interval values will be ignored, if they are specified. If a gpu is a P2P peer to the device the test will pass, otherwise it will fail. A message indicating the result will be provided for each GPUs specified. It will have the following format:

[RESULT][<timestamp>][<action name>] p2p <gpu id> <peer gpu id> peers:<p2p_result> distance:<distance> <hop_type>:<hop_dist>[ <hop_type>:<hop_dist>]

If the value of test_bandwidth is true bandwidth testing between the device and each of its peers will take place in parallel or in sequence, depending on the value of the parallel flag. During the duration of bandwidth benchmarking, informational output providing the moving average of the transfer’s bandwidth will be calculated and logged at every time increment specified by the log_interval parameter. The messages will have the following output:

[INFO  ][<timestamp>][<action name>] p2p-bandwidth [<transfer_id>] <gpu id> <peer gpu id> bidirectional: <bidirectional> <interval_bandwidth>

At the end of the test the average bytes/second will be calculated over the entire test duration, and will be logged as a result:

[RESULT][<timestamp>][<action name>] p2p-bandwidth [<transfer_id>] <gpu id> <peer gpu id> bidirectional: <bidirectional> <bandwidth> <duration>

Examples#

Example 1:

Here all source GPUs (device: all) with all destination GPUs (peers: all) are tested for p2p capability with no bandwidth testing (test_bandwidth: false).

actions:
- name: action_1
  device: all
  module: pbqt
  peers: all
  test_bandwidth: false

Possible result is:

[RESULT] [1656631.262875] [action_1] p2p 3254 3254 peers:false distance:-1
[RESULT] [1656631.262968] [action_1] p2p 3254 50599 peers:true distance:56 HyperTransport:56
[RESULT] [1656631.263039] [action_1] p2p 3254 33367 peers:true distance:56 HyperTransport:56
[RESULT] [1656631.263103] [action_1] p2p 50599 3254 peers:true distance:56 HyperTransport:56
[RESULT] [1656631.263151] [action_1] p2p 50599 50599 peers:false distance:-1
[RESULT] [1656631.263203] [action_1] p2p 50599 33367 peers:true distance:56 HyperTransport:56
[RESULT] [1656631.263265] [action_1] p2p 33367 3254 peers:true distance:56 HyperTransport:56
[RESULT] [1656631.263321] [action_1] p2p 33367 50599 peers:true distance:56 HyperTransport:56
[RESULT] [1656631.263360] [action_1] p2p 33367 33367 peers:false distance:-1

From the first line of result, we can see that GPU (ID 3254) can’t access itself. From the second line of result, we can see that source GPU (ID 3254) can access destination GPU (ID 50599).

Example 2:

Here all source GPUs (device: all) with all destination GPUs (peers: all) are tested for p2p capability including bandwidth testing (test_bandwidth: true) with bidirectional transfers (bidirectional: true) and with emmediate output for each completed transfer (log_interval: 0)

actions:
- name: action_1
  device: all
  module: pbqt
  log_interval: 0
  duration: 0
  peers: all
  test_bandwidth: true
  bidirectional: true

When run with “-d 3” switch, possible result is:

[RESULT] [1657122.364752] [action_1] p2p 3254 3254 peers:false distance:-1
[RESULT] [1657122.364845] [action_1] p2p 3254 50599 peers:true distance:56 HyperTransport:56
[RESULT] [1657122.364917] [action_1] p2p 3254 33367 peers:true distance:56 HyperTransport:56
[RESULT] [1657122.364985] [action_1] p2p 50599 3254 peers:true distance:56 HyperTransport:56
[RESULT] [1657122.365037] [action_1] p2p 50599 50599 peers:false distance:-1
[RESULT] [1657122.365094] [action_1] p2p 50599 33367 peers:true distance:56 HyperTransport:56
[RESULT] [1657122.365157] [action_1] p2p 33367 3254 peers:true distance:56 HyperTransport:56
[RESULT] [1657122.365221] [action_1] p2p 33367 50599 peers:true distance:56 HyperTransport:56
[RESULT] [1657122.365270] [action_1] p2p 33367 33367 peers:false distance:-1
[INFO  ] [1657123.644203] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  7.013 GBps
[INFO  ] [1657123.644376] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  6.615 GBps
[INFO  ] [1657123.644453] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  2.367 GBps
[INFO  ] [1657123.644522] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  7.504 GBps
[INFO  ] [1657123.644590] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  8.207 GBps
[INFO  ] [1657123.644673] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  7.680 GBps
[INFO  ] [1657124.926221] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  6.646 GBps
[INFO  ] [1657124.926368] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  8.418 GBps
[INFO  ] [1657124.926438] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  7.402 GBps
[INFO  ] [1657124.926506] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  6.161 GBps
[INFO  ] [1657124.926573] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  9.024 GBps
[INFO  ] [1657124.926640] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  8.740 GBps
[INFO  ] [1657126.208742] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  5.680 GBps
[INFO  ] [1657126.208905] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  8.011 GBps
[INFO  ] [1657126.208990] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  3.918 GBps
[INFO  ] [1657126.209066] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  6.058 GBps
[INFO  ] [1657126.209140] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  6.650 GBps
[INFO  ] [1657126.209213] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  0.000 GBps
[RESULT] [1657126.742128] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  5.767 GBps  duration: 0.368453 sec
[RESULT] [1657126.743287] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  6.013 GBps  duration: 0.498944 sec
[RESULT] [1657126.744411] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  5.278 GBps  duration: 0.380393 sec
[RESULT] [1657126.745534] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  4.160 GBps  duration: 0.484577 sec
[RESULT] [1657126.746684] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  5.219 GBps  duration: 0.407190 sec
[RESULT] [1657126.747827] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  4.001 GBps  duration: 0.562350 sec

We can see that on this particular machine there are three GPUs and six possible device-to-peer transfers.

Example 3:

Here some source GPUs (device: 50599) are targeting some destination GPUs (peers: 33367 3254) with specified log interval (log_interval: 1000) and duration (duration: 5000). Bandwidth is tested (test_bandwidth: true) but only unidirectional (bidirectional: false) without parallel execution (parallel: false).

actions:
- name: action_1
  device: 50599
  module: pbqt
  log_interval: 1000
  duration: 5000
  count: 0
  peers: 33367 3254
  test_bandwidth: true
  bidirectional: false
  parallel: false

Possible output is:

[RESULT] [1657218.801555] [action_1] p2p 50599 3254 peers:true distance:56 HyperTransport:56
[RESULT] [1657218.801655] [action_1] p2p 50599 33367 peers:true distance:56 HyperTransport:56
[INFO  ] [1657219.871532] [action_1] p2p-bandwidth  [1/2] 50599 3254  bidirectional: false  4.517 GBps
[INFO  ] [1657219.871717] [action_1] p2p-bandwidth  [2/2] 50599 33367  bidirectional: false  4.475 GBps
[INFO  ] [1657220.940263] [action_1] p2p-bandwidth  [1/2] 50599 3254  bidirectional: false  4.476 GBps
[INFO  ] [1657220.940461] [action_1] p2p-bandwidth  [2/2] 50599 33367  bidirectional: false  4.601 GBps
[INFO  ] [1657222.7589  ] [action_1] p2p-bandwidth  [1/2] 50599 3254  bidirectional: false  4.488 GBps
[INFO  ] [1657222.7760  ] [action_1] p2p-bandwidth  [2/2] 50599 33367  bidirectional: false  4.470 GBps
[INFO  ] [1657223.74647 ] [action_1] p2p-bandwidth  [1/2] 50599 3254  bidirectional: false  4.666 GBps
[INFO  ] [1657223.74810 ] [action_1] p2p-bandwidth  [2/2] 50599 33367  bidirectional: false  4.576 GBps
[RESULT] [1657224.181106] [action_1] p2p-bandwidth  [1/2] 50599 3254  bidirectional: false  4.539 GBps  duration: 1.321909 sec
[RESULT] [1657224.182255] [action_1] p2p-bandwidth  [2/2] 50599 33367  bidirectional: false  4.551 GBps  duration: 1.318517 sec

From the last line of result, we can see that source GPU (ID 50599) can access destination GPU (ID 33367) and that the bandwidth is 4.495 GBps.

Example 4:

Here, all GPUs are targeted with bidirectional transfers and parallel execution of tests:

actions:
- name: action_1
  device: all
  module: pbqt
  log_interval: 1200
  duration: 4000
  peers: all
  test_bandwidth: true
  bidirectional: true
  parallel: true

Possible output is:

[RESULT] [1657295.937184] [action_1] p2p 3254 3254 peers:false distance:-1
[RESULT] [1657295.937267] [action_1] p2p 3254 50599 peers:true distance:56 HyperTransport:56
[RESULT] [1657295.937324] [action_1] p2p 3254 33367 peers:true distance:56 HyperTransport:56
[RESULT] [1657295.937379] [action_1] p2p 50599 3254 peers:true distance:56 HyperTransport:56
[RESULT] [1657295.937429] [action_1] p2p 50599 50599 peers:false distance:-1
[RESULT] [1657295.937482] [action_1] p2p 50599 33367 peers:true distance:56 HyperTransport:56
[RESULT] [1657295.937543] [action_1] p2p 33367 3254 peers:true distance:56 HyperTransport:56
[RESULT] [1657295.937607] [action_1] p2p 33367 50599 peers:true distance:56 HyperTransport:56
[RESULT] [1657295.937655] [action_1] p2p 33367 33367 peers:false distance:-1
[INFO  ] [1657297.216212] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  4.972 GBps
[INFO  ] [1657297.216351] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  8.183 GBps
[INFO  ] [1657297.216423] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  8.911 GBps
[INFO  ] [1657297.216490] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  7.690 GBps
[INFO  ] [1657297.216558] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  7.768 GBps
[INFO  ] [1657297.216642] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  4.589 GBps
[INFO  ] [1657298.487427] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  8.778 GBps
[INFO  ] [1657298.487593] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  7.921 GBps
[INFO  ] [1657298.487730] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  8.164 GBps
[INFO  ] [1657298.487807] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  8.921 GBps
[INFO  ] [1657298.487878] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  8.487 GBps
[INFO  ] [1657298.487956] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  7.648 GBps
[INFO  ] [1657299.760175] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  7.210 GBps
[INFO  ] [1657299.760249] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  4.274 GBps
[INFO  ] [1657299.760284] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  0.000 GBps
[INFO  ] [1657299.760318] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  5.942 GBps
[INFO  ] [1657299.760349] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  0.001 GBps
[INFO  ] [1657299.760381] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  5.490 GBps
[RESULT] [1657300.293126] [action_1] p2p-bandwidth  [1/6] 3254 50599  bidirectional: true  6.964 GBps  duration: 0.287248 sec
[RESULT] [1657300.294334] [action_1] p2p-bandwidth  [2/6] 3254 33367  bidirectional: true  3.960 GBps  duration: 0.536554 sec
[RESULT] [1657300.295528] [action_1] p2p-bandwidth  [3/6] 50599 3254  bidirectional: true  5.442 GBps  duration: 0.368977 sec
[RESULT] [1657300.296691] [action_1] p2p-bandwidth  [4/6] 50599 33367  bidirectional: true  4.187 GBps  duration: 0.477756 sec
[RESULT] [1657300.297840] [action_1] p2p-bandwidth  [5/6] 33367 3254  bidirectional: true  4.942 GBps  duration: 0.607009 sec
[RESULT] [1657300.299016] [action_1] p2p-bandwidth  [6/6] 33367 50599  bidirectional: true  3.828 GBps  duration: 0.523495 sec

It can be seen that transfers [2/6] and [5/6] did not take place in the second log interval so average from the previous cycle is displayed instead and marked with “(*)”

PEBB Module#

The PCIe Bandwidth Benchmark attempts to saturate the PCIe bus with DMA transfers between system memory and a target GPU card’s memory. These are known as host-to-device or device- to-host transfers, and can be either unidirectional or bidirectional transfers. The maximum bandwidth obtained is reported.

Module Specific Keys#

Config Key Type Description
host_to_deviceBool This key indicates if host to device transfers will be considered. The default value is true.
device_to_hostBool This key indicates if device to host transfers will be considered. The default value is true.
parallelBool This option is only used if the test_bandwidth key is true.\n - true – Run all test transfers in parallel.\n - false – Run test transfers one by one.
durationInteger This option is only used if test_bandwidth is true. This key specifies the duration a transfer test should run, given in milliseconds. If this key is not specified, the default value is 10000 (10 seconds).
log_intervalInteger This option is only used if test_bandwidth is true. This is a positive integer, given in milliseconds, that specifies an interval over which the moving average of the bandwidth will be calculated and logged. The default value is 1000 (1 second). It must be smaller than the duration key.\n if this key is 0 (zero), results are displayed as soon as the test transfer is completed.
block_sizeCollection of Integers Optional. Defines list of block sizes to be used in transfer tests.\n If "all" or missing list of block sizes used in rocm_bandwidth_test is used: - 1 * 1024 - 2 * 1024 - 4 * 1024 - 8 * 1024 - 16 * 1024 - 32 * 1024 - 64 * 1024 - 128 * 1024 - 256 * 1024 - 512 * 1024 - 1 * 1024 * 1024 - 2 * 1024 * 1024 - 4 * 1024 * 1024 - 8 * 1024 * 1024 - 16 * 1024 * 1024 - 32 * 1024 * 1024 - 64 * 1024 * 1024 - 128 * 1024 * 1024 - 256 * 1024 * 1024 - 512 * 1024 * 1024
b2b_block_sizeInteger This option is only used if both 'test_bandwidth' and 'parallel' keys are true. This is a positive integer indicating size in Bytes of a data block to be transferred continuously ("back-to-back") for the duration of one test pass. If the key is not present, ordinary transfers with size indicated in 'block_size' key will be performed.
link_typeInteger This is a positive integer indicating type of link to be included in bandwidth test. Numbering follows that listed in **hsa\_amd\_link\_info\_type\_t** in **hsa\_ext\_amd.h** file.

Please note that suitable values for log_interval and duration depend on your system.

  • log_interval, in sequential mode, should be long enough to allow all transfer tests to finish at lest once or “(pending)” and “(*)” will be displayed (see below). Number of transfers depends on number of peer NUMA nodes in your system. In parallel mode, it should be roughly 1.5 times the duration of single longest individual test.

  • duration, regardless of mode should be at least, 4 * log_interval.

You may obtain indication of how long single transfer between two NUMA nodes take by running test with “-d 4” switch and observing DEBUG messages for transfer start/finish. An output may look like this:

[DEBUG ] [187024.729433] [action_1] pebb transfer 0 6 start
[DEBUG ] [187029.327818] [action_1] pebb transfer 0 6 finish
[DEBUG ] [187024.299150] [action_1] pebb transfer 1 6 start
[DEBUG ] [187029.473378] [action_1] pebb transfer 1 6 finish
[DEBUG ] [187023.227009] [action_1] pebb transfer 1 5 start
[DEBUG ] [187029.530203] [action_1] pebb transfer 1 5 finish
[DEBUG ] [187025.737675] [action_1] pebb transfer 3 5 start
[DEBUG ] [187030.134100] [action_1] pebb transfer 3 5 finish
[DEBUG ] [187027.19961 ] [action_1] pebb transfer 2 6 start
[DEBUG ] [187030.421181] [action_1] pebb transfer 2 6 finish
[DEBUG ] [187027.41475 ] [action_1] pebb transfer 2 5 start
[DEBUG ] [187031.293998] [action_1] pebb transfer 2 5 finish
[DEBUG ] [187027.71717 ] [action_1] pebb transfer 0 5 start
[DEBUG ] [187031.605326] [action_1] pebb transfer 0 5 finish

From this printout, it can be concluded that single transfer takes on average 5500ms. Values for log_interval and duration should be set accordingly.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
CPU nodeInteger Particular CPU node involved in transfer
distanceInteger NUMA distance for these two peers
hop_typeString Link type for each link hop (e.g., PCIe, HyperTransport, QPI, ...)
hop_distanceInteger NUMA distance for this particular hop
transfer_idString String with format "/" where - transfer_index - is number, starting from 1, for each device-peer combination - transfer_number - is total number of device-peer combinations
interval_bandwidthFloat The average bandwidth of a p2p transfer, during the log_interval time period.\n This field may also take values: - (pending) - this means that no measurement has taken place yet. - xxxGBps (*) - this means no measurement within current log_interval but average from previous measurements is displayed.
bandwidthFloat The average bandwidth of a p2p transfer, averaged over the entire test duration of the interval. This field may also take value: - (not measured) - this means no test transfer completed for those peers. You may need to increase test duration.
durationFloat Cumulative duration of all transfers between the two particular nodes

At the beginning, test will display link infor for every CPU/GPU pair:

[RESULT][<timestamp>][<action name>] pcie-bandwidth [<transfer_id>] <cpu node> <gpu node> <gpu id> distance:<distance> <hop_type>:<hop_dist>[ <hop_type>:<hop_dist>]

During the execution of the benchmark, informational output providing the moving average of the bandwidth of the transfer will be calculated and logged. This interval is provided by the log_interval parameter and will have the following output format:

[INFO ][<timestamp>][<action name>] pcie-bandwidth [<transfer_id>] <cpu node> <gpu id> h2d: <host_to_device> d2h: <device_to_host> <interval_bandwidth>

At the end of test, the average bytes/second will be calculated over the entire test duration, and will be logged as a result:

[RESULT][<timestamp>][<action name>] pcie-bandwidth [<transfer_id>] <cpu node> <gpu id> h2d: <host_to_device> d2h: <device_to_host> <bandwidth> <duration>

Examples#

Example 1:

Consider action:

actions:
- name: action_1
  device: all
  module: pebb
  log_interval: 0
  duration: 0
  device_to_host: false
  host_to_device: true
  parallel: false

This will initiate host to device transfer to all GPUs with immediate output (parallel: false, log_interval: 0)\n Output from this action might look like:

[RESULT] [1658774.978614] [action_1] pcie-bandwidth 0 4 3254  distance:36 HyperTransport:36
[RESULT] [1658774.978664] [action_1] pcie-bandwidth 1 4 3254  distance:20 PCIe:20
[RESULT] [1658774.978695] [action_1] pcie-bandwidth 2 4 3254  distance:36 HyperTransport:36
[RESULT] [1658774.978728] [action_1] pcie-bandwidth 3 4 3254  distance:36 HyperTransport:36
[RESULT] [1658774.978763] [action_1] pcie-bandwidth 0 5 50599  distance:36 HyperTransport:36
[RESULT] [1658774.978795] [action_1] pcie-bandwidth 1 5 50599  distance:36 HyperTransport:36
[RESULT] [1658774.978825] [action_1] pcie-bandwidth 2 5 50599  distance:20 PCIe:20
[RESULT] [1658774.978856] [action_1] pcie-bandwidth 3 5 50599  distance:36 HyperTransport:36
[RESULT] [1658774.978889] [action_1] pcie-bandwidth 0 6 33367  distance:36 HyperTransport:36
[RESULT] [1658774.978922] [action_1] pcie-bandwidth 1 6 33367  distance:36 HyperTransport:36
[RESULT] [1658774.978952] [action_1] pcie-bandwidth 2 6 33367  distance:36 HyperTransport:36
[RESULT] [1658774.978982] [action_1] pcie-bandwidth 3 6 33367  distance:20 PCIe:20
[INFO  ] [1658774.983743] [action_1] pcie-bandwidth  [1/12] 0 3254  h2d: true  d2h: false  12.233 GBps
[INFO  ] [1658774.988272] [action_1] pcie-bandwidth  [2/12] 1 3254  h2d: true  d2h: false  12.227 GBps
[INFO  ] [1658774.993197] [action_1] pcie-bandwidth  [3/12] 2 3254  h2d: true  d2h: false  11.770 GBps
[INFO  ] [1658774.998105] [action_1] pcie-bandwidth  [4/12] 3 3254  h2d: true  d2h: false  11.313 GBps
[INFO  ] [1658775.4457  ] [action_1] pcie-bandwidth  [5/12] 0 50599  h2d: true  d2h: false  12.218 GBps
[INFO  ] [1658775.9589  ] [action_1] pcie-bandwidth  [6/12] 1 50599  h2d: true  d2h: false  10.292 GBps
[INFO  ] [1658775.14627 ] [action_1] pcie-bandwidth  [7/12] 2 50599  h2d: true  d2h: false  10.456 GBps
[INFO  ] [1658775.19664 ] [action_1] pcie-bandwidth  [8/12] 3 50599  h2d: true  d2h: false  10.614 GBps
[INFO  ] [1658775.26210 ] [action_1] pcie-bandwidth  [9/12] 0 33367  h2d: true  d2h: false  12.222 GBps
[INFO  ] [1658775.31188 ] [action_1] pcie-bandwidth  [10/12] 1 33367  h2d: true  d2h: false  12.215 GBps
[INFO  ] [1658775.36137 ] [action_1] pcie-bandwidth  [11/12] 2 33367  h2d: true  d2h: false  12.219 GBps
[INFO  ] [1658775.41117 ] [action_1] pcie-bandwidth  [12/12] 3 33367  h2d: true  d2h: false  12.219 GBps
[RESULT] [1658775.42219 ] [action_1] pcie-bandwidth  [1/12] 0 3254  h2d: true  d2h: false  12.233 GBps  duration: 0.000780 sec
[RESULT] [1658775.42235 ] [action_1] pcie-bandwidth  [2/12] 1 3254  h2d: true  d2h: false  12.227 GBps  duration: 0.000780 sec
[RESULT] [1658775.42246 ] [action_1] pcie-bandwidth  [3/12] 2 3254  h2d: true  d2h: false  11.770 GBps  duration: 0.000810 sec
[RESULT] [1658775.42256 ] [action_1] pcie-bandwidth  [4/12] 3 3254  h2d: true  d2h: false  11.313 GBps  duration: 0.000843 sec
[RESULT] [1658775.42271 ] [action_1] pcie-bandwidth  [5/12] 0 50599  h2d: true  d2h: false  12.218 GBps  duration: 0.000781 sec
[RESULT] [1658775.42286 ] [action_1] pcie-bandwidth  [6/12] 1 50599  h2d: true  d2h: false  10.292 GBps  duration: 0.000927 sec
[RESULT] [1658775.42297 ] [action_1] pcie-bandwidth  [7/12] 2 50599  h2d: true  d2h: false  10.456 GBps  duration: 0.000912 sec
[RESULT] [1658775.42309 ] [action_1] pcie-bandwidth  [8/12] 3 50599  h2d: true  d2h: false  10.614 GBps  duration: 0.000898 sec
[RESULT] [1658775.42321 ] [action_1] pcie-bandwidth  [9/12] 0 33367  h2d: true  d2h: false  12.222 GBps  duration: 0.000780 sec
[RESULT] [1658775.42332 ] [action_1] pcie-bandwidth  [10/12] 1 33367  h2d: true  d2h: false  12.215 GBps  duration: 0.000781 sec
[RESULT] [1658775.42344 ] [action_1] pcie-bandwidth  [11/12] 2 33367  h2d: true  d2h: false  12.219 GBps  duration: 0.000780 sec
[RESULT] [1658775.42355 ] [action_1] pcie-bandwidth  [12/12] 3 33367  h2d: true  d2h: false  12.219 GBps  duration: 0.000780 sec

Example 2:

Consider action:

actions:
- name: action_1
  device: all
  module: pebb
  log_interval: 500
  duration: 5000
  device_to_host: true
  host_to_device: true
  parallel: true

Here, although parallel execution of transfers is requested, log_interval is to short for some transfers to complete. For them, cumulative average is displayed and marked with (*):

[RESULT] [1659672.517170] [action_1] pcie-bandwidth 0 4 3254  distance:36 HyperTransport:36
[RESULT] [1659672.517222] [action_1] pcie-bandwidth 1 4 3254  distance:20 PCIe:20
[RESULT] [1659672.517257] [action_1] pcie-bandwidth 2 4 3254  distance:36 HyperTransport:36
[RESULT] [1659672.517290] [action_1] pcie-bandwidth 3 4 3254  distance:36 HyperTransport:36
[RESULT] [1659672.517324] [action_1] pcie-bandwidth 0 5 50599  distance:36 HyperTransport:36
[RESULT] [1659672.517357] [action_1] pcie-bandwidth 1 5 50599  distance:36 HyperTransport:36
[RESULT] [1659672.517388] [action_1] pcie-bandwidth 2 5 50599  distance:20 PCIe:20
[RESULT] [1659672.517419] [action_1] pcie-bandwidth 3 5 50599  distance:36 HyperTransport:36
[RESULT] [1659672.517452] [action_1] pcie-bandwidth 0 6 33367  distance:36 HyperTransport:36
[RESULT] [1659672.517483] [action_1] pcie-bandwidth 1 6 33367  distance:36 HyperTransport:36
[RESULT] [1659672.517515] [action_1] pcie-bandwidth 2 6 33367  distance:36 HyperTransport:36
[RESULT] [1659672.517546] [action_1] pcie-bandwidth 3 6 33367  distance:20 PCIe:20
[INFO  ] [1659673.49782 ] [action_1] pcie-bandwidth  [1/12] 0 3254  h2d: true  d2h: true  1.489 GBps
[INFO  ] [1659673.49814 ] [action_1] pcie-bandwidth  [2/12] 1 3254  h2d: true  d2h: true  2.701 GBps
...
[INFO  ] [1659673.582639] [action_1] pcie-bandwidth  [1/12] 0 3254  h2d: true  d2h: true  1.489 GBps (*)
[INFO  ] [1659673.582686] [action_1] pcie-bandwidth  [2/12] 1 3254  h2d: true  d2h: true  16.367 GBps
[INFO  ] [1659673.582700] [action_1] pcie-bandwidth  [3/12] 2 3254  h2d: true  d2h: true  17.300 GBps
...
[INFO  ] [1659677.851697] [action_1] pcie-bandwidth  [1/12] 0 3254  h2d: true  d2h: true  16.793 GBps
[INFO  ] [1659677.851727] [action_1] pcie-bandwidth  [2/12] 1 3254  h2d: true  d2h: true  16.872 GBps (*)
[INFO  ] [1659677.851741] [action_1] pcie-bandwidth  [3/12] 2 3254  h2d: true  d2h: true  14.796 GBps (*)
[INFO  ] [1659677.851754] [action_1] pcie-bandwidth  [4/12] 3 3254  h2d: true  d2h: true  20.358 GBps
[INFO  ] [1659677.851770] [action_1] pcie-bandwidth  [5/12] 0 50599  h2d: true  d2h: true  15.632 GBps (*)
[INFO  ] [1659677.851828] [action_1] pcie-bandwidth  [6/12] 1 50599  h2d: true  d2h: true  14.541 GBps (*)
...
[RESULT] [1659678.148280] [action_1] pcie-bandwidth  [1/12] 0 3254  h2d: true  d2h: true  16.309 GBps  duration: 0.061316 sec
[RESULT] [1659678.148318] [action_1] pcie-bandwidth  [2/12] 1 3254  h2d: true  d2h: true  16.871 GBps  duration: 0.118547 sec
[RESULT] [1659678.148332] [action_1] pcie-bandwidth  [3/12] 2 3254  h2d: true  d2h: true  13.360 GBps  duration: 0.149705 sec
[RESULT] [1659678.148349] [action_1] pcie-bandwidth  [4/12] 3 3254  h2d: true  d2h: true  15.371 GBps  duration: 0.130115 sec
[RESULT] [1659678.148363] [action_1] pcie-bandwidth  [5/12] 0 50599  h2d: true  d2h: true  15.631 GBps  duration: 0.127954 sec
[RESULT] [1659678.148377] [action_1] pcie-bandwidth  [6/12] 1 50599  h2d: true  d2h: true  14.185 GBps  duration: 0.140989 sec
[RESULT] [1659678.148390] [action_1] pcie-bandwidth  [7/12] 2 50599  h2d: true  d2h: true  15.242 GBps  duration: 0.131245 sec
[RESULT] [1659678.148404] [action_1] pcie-bandwidth  [8/12] 3 50599  h2d: true  d2h: true  16.071 GBps  duration: 0.124452 sec
[RESULT] [1659678.148418] [action_1] pcie-bandwidth  [9/12] 0 33367  h2d: true  d2h: true  16.505 GBps  duration: 0.121178 sec
[RESULT] [1659678.148432] [action_1] pcie-bandwidth  [10/12] 1 33367  h2d: true  d2h: true  16.720 GBps  duration: 0.059807 sec
[RESULT] [1659678.148445] [action_1] pcie-bandwidth  [11/12] 2 33367  h2d: true  d2h: true  15.604 GBps  duration: 0.128168 sec
[RESULT] [1659678.148458] [action_1] pcie-bandwidth  [12/12] 3 33367  h2d: true  d2h: true  16.193 GBps  duration: 0.123525 sec

Please note that in link information results, some records could be marked with ®. This means, that communication is possible if initiated by the destination NUMA node HSA agent.

GST Module#

The GPU Stress Test modules purpose is to bring the CUs of the specified GPU(s) to a target performance level in gigaflops by doing large matrix multiplications using SGEMM/DGEMM (Single/Double-precision General Matrix Multiplication) available in a library like rocBlas. The GPU stress module may be configured so it does not copy the source arrays to the GPU before every matrix multiplication. This allows the GPU performance to not be capped by device to host bandwidth transfers. The module calculates how many matrix operations per second are necessary to achieve the configured performance target and fails if it cannot achieve that target. \n\n

This module should be used in conjunction with the GPU Monitor, to watch for thermal, power and related anomalies while the target GPU(s) are under realistic load conditions. By setting the appropriate parameters a user can ensure that all GPUs in a node or cluster reach desired performance levels. Further analysis of the generated stats can also show variations in the required power, clocks or temperatures to reach these targets, and thus highlight GPUs or nodes that are operating less efficiently.

Module Specific Keys#

Module specific keys are described in the table below:

Config Key Type Description
target_stressFloat The maximum relative performance the GPU will attempt to achieve in gigaflops. This parameter is required.
copy_matrixBool This parameter indicates if each operation should copy the matrix data to the GPU before executing. The default value is true.
ramp_intervalInteger This is an time interval, specified in milliseconds, given to the test to reach the given target_stress gigaflops. The default value is 5000 (5 seconds). This time is counted against the duration of the test. If the target gflops, or stress, is not achieved in this time frame, the test will fail. If the target stress (gflops) is achieved the test will attempt to run for the rest of the duration specified by the action, sustaining the stress load during that time.
toleranceFloat A value indicating how much the target_stress can fluctuate after the ramp period for the test to succeed. The default value is 0.1 or 10%.
max_violationsInteger The number of tolerance violations that can occur after the ramp_interval for the test to still pass. The default value is 0.
log_intervalInteger This is a positive integer, given in milliseconds, that specifies an interval over which the moving average of the bandwidth will be calculated and logged.
matrix_sizeInteger Size of the matrices of the SGEMM operations. The default value is 5760.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
target_stressTime Series Floats The average gflops over the last log interval.
max_gflopsFloat The maximum sustained performance obtained by the GPU during the test.
stress_violationsInteger The number of gflops readings that violated the tolerance of the test after the ramp interval.
flops_per_opInteger Flops (floating point operations) per operation queued to the GPU queue. One operation is one call to SGEMM/DGEMM.
bytes_copied_per_opInteger Calculated number of ops/second necessary to achieve target gigaflops.
try_ops_per_secFloat Calculated number of ops/second necessary to achieve target gigaflops.
passBool 'true' if the GPU achieves its desired sustained performance level.

An informational message indicating will be emitted when the test starts execution:

[INFO ][<timestamp>][<action name>] gst <gpu id> start <target_stress> copy matrix: <copy_matrix>

During the execution of the test, informational output providing the moving average the GPU(s) gflops will be logged at each log_interval:

[INFO ][<timestamp>][<action name>] gst Gflops: <interval_gflops>

When the target gflops is achieved, the following message will be logged:

[INFO ][<timestamp>][<action name>] gst <gpu id> target achieved <target_stress>

If the target gflops, or stress, is not achieved in the “ramp_interval” provided, the test will terminate and the following message will be logged:

[INFO ][<timestamp>][<action name>] gst <gpu id> ramp time exceeded <ramp_time>

In this case the test will fail.\n

If the target stress (gflops) is achieved the test will attempt to run for the rest of the duration specified by the action, sustaining the stress load during that time. If the stress level violates the bounds set by the tolerance level during that time a violation message will be logged:

[INFO ][<timestamp>][<action name>] gst <gpu id> stress violation <interval_gflops>

When the test completes, the following result message will be printed:

[RESULT][<timestamp>][<action name>] gst <gpu id> Gflop: <max_gflops> flops_per_op:<flops_per_op> bytes_copied_per_op: <bytes_copied_per_op> try_ops_per_sec: <try_ops_per_sec> pass: <pass>

The test will pass if the target_stress is reached before the end of the ramp_interval and the stress_violations value is less than the given max_violations value. Otherwise, the test will fail.

Examples#

When running the GST module, users should provide at least an action name, the module name (gst), a list of GPU IDs, the test duration and a target stress value (gigaflops). Thus, the most basic configuration file looks like this:

actions:
- name: action_gst_1
  module: gst
  device: all
  target_stress: 3500
  duration: 8000

For the above configuration file, all the missing configuration keys will have their default values (e.g.: copy_matrix=true, matrix_size=5760 etc.). For more information about the default values please consult the dedicated sections (3.3 Common Configuration Keys and 5.1 Configuration keys).

When the RVS tool runs against such a configuration file, it will do the following:

  • run the stress test on all available (and compatible) AMD GPUs, one after the other

  • log a start message containing the GPU ID, the target_stress and the value of the copy_matrix:

    [INFO ] [164337.932824] action_gst_1 gst 50599 start 3500.000000 copy matrix:true

  • emit, each log_interval (e.g.: 1000ms), a message containing the gigaflops value that the current GPU achieved:

    [INFO ] [164355.111207] action_gst_1 gst 33367 Gflops 3535.670231

  • log a message as soon as the current GPU reaches the given target_stress:

    [INFO ] [164350.804843] action_gst_1 gst 33367 target achieved 500.000000

  • log a ramp time exceeded message if the GPU was not able to reach the target_stress in the ramp_interval time frame (e.g.: 5000). In such a case, the test will also terminate:

    [INFO ] [164013.788870] action_gst_1 gst 3254 ramp time exceeded 5000

  • log the test result, when the stress test completes. The message contains the test’s overall result and some other statistics according to 5.2 Output keys:

    [RESULT] [164355.647523] action_gst_1 gst 33367 Gflop: 4066.020766 flops_per_op: 382.205952x1e9 bytes_copied_per_op: 398131200 try_ops_per_sec: 9.157367 pass: TRUE

  • log a stress violation message when the current gigaflops (for the last log_interval, e.g.; 1000ms) violates the bounds set by the tolerance configuration key (e.g.: 0.1). Please note that this message is not logged during the ramp_interval time frame:

    [INFO ] [164013.788870] action_gst_1 gst 3254 stress violation 2500

If a mandatory configuration key is missing, the RVS tool will log an error message and terminate the execution of the current module. For example, the following configuration file will cause the RVS to terminate with the following error message:
RVS-GST: action: action_gst_1 key ‘target_stress’ was not found

actions:
- name: action_gst_1
  module: gst
  device: all
  duration: 8000

A more complex configuration file looks like this:

actions:
- name: action_1
  device: 50599 33367
  module: gst
  parallel: false
  count: 12
  wait: 100
  duration: 7000
  ramp_interval: 3000
  log_interval: 1000
  max_violations: 2
  copy_matrix: false
  target_stress: 5000
  tolerance: 0.07
  matrix_size: 5760

For this configuration file, the RVS tool:

  • will run the stress test only for the GPUs having the ID 50599 or 33367. To get all the available GPU IDs, run RVS tool with -g option

  • will run the test on the selected GPUs, one after the other

  • will run each test, 12 times

  • will only copy the matrices to the GPUs at the beginning of the test

  • will wait 100ms before each test execution

  • will try to reach 5000 gflops in maximum 3000ms

  • if target_stress (5000) is achieved in the ramp_interval (3000 ms) it will attempt to run the test for the rest of the duration, sustaining the stress load during that time

  • will allow a 7% target_stress tolerance (each target_stress violation will generate a stress violation message as shown in the first example)

  • will allow only 2 target_stress violations. Exceeding the max_violations will not terminate the test, but the RVS will mark the test result as “fail”.

The output for such a configuration key may look like this:

[INFO ] [172061.758830] action_1 gst 50599 start 5000.000000 copy matrix:false
[INFO ] [172063.547668] action_1 gst 50599 Gflops 6471.614725
[INFO ] [172064.577715] action_1 gst 50599 target achieved 5000.000000
[INFO ] [172065.609224] action_1 gst 50599 Gflops 5189.993529
[INFO ] [172066.634360] action_1 gst 50599 Gflops 5220.373979
[INFO ] [172067.659262] action_1 gst 50599 Gflops 5225.472000
[INFO ] [172068.694305] action_1 gst 50599 Gflops 5169.935583
[RESULT] [172069.573967] action_1 gst 50599 Gflop: 6471.614725 flops_per_op: 382.205952x1e9 bytes_copied_per_op: 398131200 try_ops_per_sec: 13.081952 pass: TRUE
[INFO ] [172069.574369] action_1 gst 33367 start 5000.000000 copy matrix:false
[INFO ] [172071.409483] action_1 gst 33367 Gflops 6558.348080
[INFO ] [172072.438104] action_1 gst 33367 target achieved 5000.000000
[INFO ] [172073.465033] action_1 gst 33367 Gflops 5215.285895
[INFO ] [172074.501571] action_1 gst 33367 Gflops 5164.945297
[INFO ] [172075.529468] action_1 gst 33367 Gflops 5210.207720
[INFO ] [172076.558102] action_1 gst 33367 Gflops 5205.139424
[RESULT] [172077.448182] action_1 gst 33367 Gflop: 6558.348080 flops_per_op: 382.205952x1e9 bytes_copied_per_op: 398131200 try_ops_per_sec: 13.081952 pass: TRUE

When setting the parallel to false, the RVS will run the stress tests on all selected GPUs in parallel and the output may look like this:

[INFO ] [173381.407428] action_1 gst 50599 start 5000.000000 copy matrix:false
[INFO ] [173381.407744] action_1 gst 33367 start 5000.000000 copy matrix:false
[INFO ] [173383.245771] action_1 gst 33367 Gflops 6558.348080
[INFO ] [173383.256935] action_1 gst 50599 Gflops 6484.532120
[INFO ] [173384.274202] action_1 gst 33367 target achieved 5000.000000
[INFO ] [173384.286014] action_1 gst 50599 target achieved 5000.000000
[INFO ] [173385.301038] action_1 gst 33367 Gflops 5215.285895
[INFO ] [173385.315794] action_1 gst 50599 Gflops 5200.080980
[INFO ] [173386.337638] action_1 gst 33367 Gflops 5164.945297
[INFO ] [173386.353274] action_1 gst 50599 Gflops 5159.964636
[INFO ] [173387.365494] action_1 gst 33367 Gflops 5210.207720
[INFO ] [173387.383437] action_1 gst 50599 Gflops 5195.032357
[INFO ] [173388.401250] action_1 gst 33367 Gflops 5169.935583
[INFO ] [173388.421599] action_1 gst 50599 Gflops 5154.993572
[RESULT] [173389.282710] action_1 gst 33367 Gflop: 6558.348080 flops_per_op: 382.205952x1e9 bytes_copied_per_op: 398131200 try_ops_per_sec: 13.081952 pass: TRUE
[RESULT] [173389.305479] action_1 gst 50599 Gflop: 6484.532120 flops_per_op: 382.205952x1e9 bytes_copied_per_op: 398131200 try_ops_per_sec: 13.081952 pass: TRUE

It is important that all the configuration keys will be adjusted/fine-tuned according to the actual GPUs and HW platform capabilities. For example, a matrix size of 5760 should fit the VEGA 10 GPUs while 8640 should work with the VEGA 20 GPUs.

IET Module#

The Input EDPp Test can be used to characterize the peak power capabilities of a GPU to different levels of use. This tool can leverage the functionality of the GST to drive the compute load on the GPU, but the test will use different configuration and output keys and should focus on driving power usage rather than calculating compute load. The purpose of the IET module is to bring the GPU(s) to a pre-configured power level in watts by gradually increasing the compute load on the GPUs until the desired power level is achieved. This verifies that the GPUs can sustain a power level for a reasonable amount of time without problems like thermal violations arising.\n

This module should be used in conjunction with the GPU Monitor, to watch for thermal, power and related anomalies while the target GPU(s) are under realistic load conditions. By setting the appropriate parameters a user can ensure that all GPUs in a node or cluster reach desired performance levels. Further analysis of the generated stats can also show variations in the required power, clocks or temperatures to reach these targets, and thus highlight GPUs or nodes that are operating less efficiently.

Module Specific Keys#

Module specific keys are described in the table below:

Config Key Type Description
target_powerFloat This is a floating point value specifying the target sustained power level for the test.
ramp_intervalInteger This is an time interval, specified in milliseconds, given to the test to determine the compute load that will sustain the target power. The default value is 5000 (5 seconds). This time is counted against the duration of the test.
toleranceFloat A value indicating how much the target_power can fluctuate after the ramp period for the test to succeed. The default value is 0.1 or 10%.
max_violationsInteger The number of tolerance violations that can occur after the ramp_interval for the test to still pass. The default value is 0.
sample_intervalInteger The sampling rate for target_power values given in milliseconds. The default value is 100 (.1 seconds).
log_intervalInteger This is a positive integer, given in milliseconds, that specifies an interval over which the moving average of the bandwidth will be calculated and logged.

Output#

Module specific output keys are described in the table below:

Output Key Type Description
current_powerTime Series Floats The current measured power of the GPU.
power_violationsInteger The number of power reading that violated the tolerance of the test after the ramp interval.
passBool 'true' if the GPU achieves its desired sustained power level in the ramp interval.

Examples#

Example 1:

A regular IET configuration file looks like this:

actions:
- name: action_1
  device: all
  module: iet
  parallel: false
  count: 2
  wait: 100
  duration: 10000
  ramp_interval: 5000
  sample_interval: 500
  log_interval: 500
  max_violations: 1
  target_power: 135
  tolerance: 0.1
  matrix_size: 5760

Please note:

  • when setting the ‘device’ configuration key to ‘all’, the RVS will detect all the AMD compatible GPUs and run the test on all of them

  • the test will run 2 times on each GPU (count = 2)

  • only one power violation is allowed. If the total number of violations is bigger than 1 the IET test result will be marked as ‘failed’

When the RVS tool runs against such a configuration file, it will do the following:

  • run the test on all AMD compatible GPUs

  • log a start message containing the GPU ID and the target_power, e.g.:

    [INFO ] [167316.308057] action_1 iet 50599 start 135.000000

  • emit, each log_interval (e.g.: 500ms), a message containing the power for the current GPU

    [INFO ] [167319.266707] action_1 iet 50599 current power 136.878342

  • log a message as soon as the current GPU reaches the given target_power

    [INFO ] [167318.793062] action_1 iet 50599 target achieved 135.000000

  • log a ‘ramp time exceeded’ message if the GPU was not able to reach the target_power in the ramp_interval time frame (e.g.: 5000ms). In such a case, the test will also terminate

    [INFO ] [167648.832413] action_1 iet 50599 ramp time exceeded 5000

  • log a ‘power violation message’ when the current power (for the last sample_interval, e.g.; 500ms) violates the bounds set by the tolerance configuration key (e.g.: 0.1). Please note that this message is never logged during the ramp_interval time frame

    [INFO ] [161251.971277] action_1 iet 3254 power violation 73.783211

  • log the test result, when the stress test completes.

    [RESULT] [167305.260051] action_1 iet 33367 pass: TRUE

The output for such a configuration file may look like this:

[INFO ] [167261.27161 ] action_1 iet 33367 start 135.000000
[INFO ] [167263.516803] action_1 iet 33367 current power 136.934479
[INFO ] [167263.521355] action_1 iet 33367 target achieved 135.000000
[INFO ] [167264.16925 ] action_1 iet 33367 current power 138.421844
[INFO ] [167264.517018] action_1 iet 33367 current power 138.394608
...
[INFO ] [167271.518402] action_1 iet 33367 current power 139.231918
[RESULT] [167272.67686 ] action_1 iet 33367 pass: TRUE
[INFO ] [167272.68029 ] action_1 iet 3254 start 135.000000
[INFO ] [167274.552026] action_1 iet 3254 current power 139.363525
[INFO ] [167274.552059] action_1 iet 3254 target achieved 135.000000
[INFO ] [167275.52168 ] action_1 iet 3254 current power 138.661453
[INFO ] [167275.552241] action_1 iet 3254 current power 138.857635
...
[INFO ] [167282.553983] action_1 iet 3254 current power 140.069687
[RESULT] [167283.95763 ] action_1 iet 3254 pass: TRUE
[INFO ] [167283.96158 ] action_1 iet 50599 start 135.000000
[INFO ] [167285.532999] action_1 iet 50599 current power 137.205032
[INFO ] [167285.543084] action_1 iet 50599 target achieved 135.000000
[INFO ] [167286.33050 ] action_1 iet 50599 current power 136.137115
...
[INFO ] [167293.534672] action_1 iet 50599 current power 139.753464
[RESULT] [167294.131420] action_1 iet 50599 pass: TRUE

Example 2:

Another configuration file, which may raise some ‘power violation’ messages (due to the small tolerance value) looks like this

- name: action_1
  device: all
  module: iet
  parallel: false
  count: 1
  wait: 100
  duration: 8000
  ramp_interval: 5000
  sample_interval: 700
  log_interval: 700
  max_violations: 1
  target_power: 80
  tolerance: 0.06
  matrix_size: 5760

The output for such a configuration file may look like this:

[INFO ] [161236.677785] action_1 iet 33367 start 80.000000
[INFO ] [161239.350055] action_1 iet 33367 current power 84.186142
[INFO ] [161239.354542] action_1 iet 33367 target achieved 80.000000
...
[INFO ] [161241.450517] action_1 iet 33367 current power 77.001945
[INFO ] [161241.459600] action_1 iet 33367 power violation 75.163689
[INFO ] [161242.150642] action_1 iet 33367 current power 82.063576
[RESULT] [161245.698113] action_1 iet 33367 pass: TRUE
[INFO ] [161245.698525] action_1 iet 3254 start 80.000000
[INFO ] [161248.394003] action_1 iet 3254 current power 78.842796
[INFO ] [161248.418631] action_1 iet 3254 target achieved 80.000000
[INFO ] [161249.94149 ] action_1 iet 3254 current power 79.938454
...
[INFO ] [161249.794201] action_1 iet 3254 current power 76.511711
[INFO ] [161249.818803] action_1 iet 3254 power violation 74.279594
[INFO ] [161250.494263] action_1 iet 3254 current power 74.615120
...
[INFO ] [161254.117386] action_1 iet 3254 power violation 73.682312
[RESULT] [161254.738939] action_1 iet 3254 pass: FALSE
[INFO ] [161254.739387] action_1 iet 50599 start 80.000000
[INFO ] [161257.374079] action_1 iet 50599 current power 81.560165
[INFO ] [161257.392085] action_1 iet 50599 target achieved 80.000000
[INFO ] [161258.774304] action_1 iet 50599 current power 75.057304
...
[INFO ] [161262.974833] action_1 iet 50599 current power 80.200668
[RESULT] [161263.771631] action_1 iet 50599 pass: TRUE

Important notes:

  • all the missing configuration keys (if any) will have their default values. For more information about the default values please consult the dedicated sections (3.3 Common Configuration Keys and 13.1 Module specific keys).

  • if a mandatory configuration key is missing, the RVS tool will log an error message and terminate the execution of the current module. For example, if the target_power is missing, the RVS to terminate with the following error message: “RVS-IET: action: action_1 key ‘target_power’ was not found”

  • it is important that all the configuration keys will be adjusted/fine-tuned according to the actual GPUs and HW platform capabilities.

*) for example, a matrix size of 5760 should fit the VEGA 10 GPUs while 8640 should work with the VEGA 20 GPUs

*) for small target_power values (e.g.: 30-40W), the sample_interval should be increased, otherwise the IET may fail either to achieve the given target_power or to sustain it (e.g.: ramp_interval = 1500 for target_power = 40)

*) in case there are problems reaching/sustaining the given target_power

**) please increase the ramp_interval and/or the tolerance value(s) and try again (in case of a ‘ramp time exceeded’ message)

**) please increase the tolerance value (in case too many ‘power violation message’ are logged out)